Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3397604
Value: Gas, convection
Create:
Burner #3397605
Value: Gas
Create:
Number of circuits #3397606
Value: Double-circuit
Create:
Max. thermal power #3397607
Value: 32 kW
Create:
Max. thermal load #3397608
Value: 34.40 kW
Create:
The combustion chamber #3397609
Value: Closed
Create:
Efficiency #3397610
Value: 93.1 %
Create:
Control #3397611
Value: Electronic
Create:
Installation #3397612
Value: Floor
Create:
Primary heat exchanger material #3397613
Value: Cast iron
Create:
Secondary heat exchanger material #3397614
Value: Stainless steel
Create:
Mains voltage #3397615
Value: Single-phase
Create:
Peculiarities #3397616
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3397617
Value: 60 l
Create:
Expansion tank volume #3397618
Value: 12 l
Create:
Equipment #3397619
Value: Built-in boiler, display
Create:
Fuel #3397620
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3397621
Value: 3.64 cu. m/hour
Create:
LPG consumption #3397622
Value: 2.7 kg/hour
Create:
Nominal pressure of natural gas #3397623
Value: 20 mbar
Create:
Permissible LPG pressure #3397624
Value: 29 mbar
Create:
Heat carrier temperature #3397625
Value: 40 - 90 °С
Create:
Temperature in the DHW circuit #3397626
Value: 50 - 65 °С
Create:
Hot water capacity at t 30°C #3397627
Value: 24.5 l/min
Create:
Max. water pressure in the DHW circuit #3397628
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3397629
Value: 3 bar
Create:
Gas connection #3397630
Value: 1/2"
Create:
Heating circuit connection #3397631
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3397632
Value: 3/4"
Create:
Coaxial chimney diameter #3397633
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3397634
Value: Yes
Create:
Dimensions WxHxD #3397635
Value: 600x1370x800mm
Create:
Weight #3397636
Value: 225.5 kg
Create:
Additional Information #3397637
Value: Expansion tank of the DHW circuit with a volume of 5 liters; DHW circuit pump
Create:
Image #6321243
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id276048654913446974/orig
Create:
Image #6321244
URL: https://avatars.mds.yandex.net/get-mpic/1926869/img_id5204022406688558101/orig
Create:
Preview image #6321245
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id276048654913446974/orig
Donny Darko 30 April 2023 08:23:07
Name: Gas Fondital Bali BTSFE 32 32 kW double-circuit; Catalog: Heating boilers