Change history for item: Gas Fondital Itaca KC 24

  1. Donny Darko 08 July 2023 05:33:13
    1. Create: Description #3397311
      Value: Type of heating boiler: gas, max. heating power: 24.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3397312
      Value: Gas, condensing
    3. Create: Burner #3397313
      Value: Gas
    4. Create: Number of circuits #3397314
      Value: Double-circuit
    5. Create: Thermal power #3397315
      Value: 2.70 - 24.90 kW
    6. Create: The combustion chamber #3397316
      Value: Closed
    7. Create: Efficiency #3397317
      Value: 105.1 %
    8. Create: Control #3397318
      Value: Electronic
    9. Create: Installation #3397319
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3397320
      Value: Stainless steel
    11. Create: Secondary heat exchanger material #3397321
      Value: Stainless steel
    12. Create: Mains voltage #3397322
      Value: Single-phase
    13. Create: Peculiarities #3397323
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3397324
      Value: 10 l
    15. Create: Equipment #3397325
      Value: Display
    16. Create: Fuel #3397326
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3397327
      Value: 2.51 cu. m/hour
    18. Create: LPG consumption #3397328
      Value: 1.84 kg/hour
    19. Create: Nominal pressure of natural gas #3397329
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3397330
      Value: 37 mbar
    21. Create: Heat carrier temperature #3397331
      Value: 20 - 78 °С
    22. Create: Temperature in the DHW circuit #3397332
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3397333
      Value: 16.1 l/min
    24. Create: Hot water capacity at t 30°C #3397334
      Value: 13.4 l/min
    25. Create: Hot water capacity at t 35°C #3397335
      Value: 11.5 l/min
    26. Create: Hot water capacity at t 40°C #3397336
      Value: 10 l/min
    27. Create: Hot water capacity at t 45°C #3397337
      Value: 8.9 l/min
    28. Create: Max. water pressure in the DHW circuit #3397338
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3397339
      Value: 3 bar
    30. Create: Heating circuit connection #3397340
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3397341
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3397342
      Value: 60/100 mm and 80/125 mm
    33. Create: Dimensions WxHxD #3397343
      Value: 420x750x315 mm
    34. Create: Weight #3397344
      Value: 34.5 kg
    35. Create: Image #6321216
      URL: https://avatars.mds.yandex.net/get-mpic/1589815/img_id3251155371766982301/orig
    36. Create: Image #6321217
      URL: https://avatars.mds.yandex.net/get-mpic/1925870/img_id6461384870256925351/orig
    37. Create: Preview image #6321218
      URL: https://avatars.mds.yandex.net/get-mpic/1589815/img_id3251155371766982301/orig
  2. Donny Darko 30 April 2023 08:23:04
    Name: Gas Fondital Itaca KC 24; Catalog: Heating boilers