Change history for item: Gas Fondital Madeira Solar KRBS MZ 32

  1. Donny Darko 08 July 2023 05:31:52
    1. Create: Description #3396685
      Value: Type of heating boiler: gas, max. heating power: 32.30 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3396686
      Value: Gas, condensing
    3. Create: Burner #3396687
      Value: Gas
    4. Create: Number of circuits #3396688
      Value: Double-circuit
    5. Create: Thermal power #3396689
      Value: 3.90 - 32.30 kW
    6. Create: Max. thermal load #3396690
      Value: 30.40 kW
    7. Create: The combustion chamber #3396691
      Value: Closed
    8. Create: Efficiency #3396692
      Value: 106.2 %
    9. Create: Control #3396693
      Value: Electronic
    10. Create: Installation #3396694
      Value: Floor
    11. Create: Primary heat exchanger material #3396695
      Value: Stainless steel
    12. Create: Mains voltage #3396696
      Value: Single-phase
    13. Create: Peculiarities #3396697
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3396698
      Value: 300 l
    15. Create: Expansion tank volume #3396699
      Value: 22 l
    16. Create: Equipment #3396700
      Value: Built-in boiler, display
    17. Create: Fuel #3396701
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3396702
      Value: 3.22 cu. m/hour
    19. Create: LPG consumption #3396703
      Value: 2.36 kg/h
    20. Create: Nominal pressure of natural gas #3396704
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3396705
      Value: 37 mbar
    22. Create: Heat carrier temperature #3396706
      Value: 20 - 78 °С
    23. Create: Temperature in the DHW circuit #3396707
      Value: 35 - 65 °С
    24. Create: Hot water capacity at t 30°C #3396708
      Value: 23.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3396709
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3396710
      Value: 3 bar
    27. Create: Gas connection #3396711
      Value: 1/2"
    28. Create: Heating circuit connection #3396712
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3396713
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3396714
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3396715
      Value: Yes
    32. Create: Dimensions WxHxD #3396716
      Value: 600x1875x985 mm
    33. Create: Weight #3396717
      Value: 276 kg
    34. Create: Additional Information #3396718
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    35. Create: Image #6321165
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id3354388545088948118/orig
    36. Create: Preview image #6321166
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id3354388545088948118/orig
  2. Donny Darko 30 April 2023 08:22:58
    Name: Gas Fondital Madeira Solar KRBS MZ 32; Catalog: Heating boilers