Change history for item: Gas Fondital Madeira Solar KRBS MZ 12

  1. Donny Darko 08 July 2023 05:31:40
    1. Create: Description #3396583
      Value: Type of heating boiler: gas, max. heating power: 12.60 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3396584
      Value: Gas, condensing
    3. Create: Burner #3396585
      Value: Gas
    4. Create: Number of circuits #3396586
      Value: Double-circuit
    5. Create: Thermal power #3396587
      Value: 1.80 - 12.60 kW
    6. Create: Max. thermal load #3396588
      Value: 12 kW
    7. Create: The combustion chamber #3396589
      Value: Closed
    8. Create: Efficiency #3396590
      Value: 105.1 %
    9. Create: Control #3396591
      Value: Electronic
    10. Create: Installation #3396592
      Value: Floor
    11. Create: Primary heat exchanger material #3396593
      Value: Stainless steel
    12. Create: Mains voltage #3396594
      Value: Single-phase
    13. Create: Peculiarities #3396595
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3396596
      Value: 300 l
    15. Create: Expansion tank volume #3396597
      Value: 22 l
    16. Create: Equipment #3396598
      Value: Built-in boiler, display
    17. Create: Fuel #3396599
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3396600
      Value: 1.27 cu. m/hour
    19. Create: LPG consumption #3396601
      Value: 0.93 kg/h
    20. Create: Nominal pressure of natural gas #3396602
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3396603
      Value: 37 mbar
    22. Create: Heat carrier temperature #3396604
      Value: 20 - 78 °С
    23. Create: Temperature in the DHW circuit #3396605
      Value: 35 - 65 °С
    24. Create: Hot water capacity at t 30°C #3396606
      Value: 23.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3396607
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3396608
      Value: 3 bar
    27. Create: Gas connection #3396609
      Value: 1/2"
    28. Create: Heating circuit connection #3396610
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3396611
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3396612
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3396613
      Value: Yes
    32. Create: Dimensions WxHxD #3396614
      Value: 600x1875x985 mm
    33. Create: Weight #3396615
      Value: 276 kg
    34. Create: Additional Information #3396616
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    35. Create: Image #6321159
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id3354388545088948118/orig
    36. Create: Preview image #6321160
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id3354388545088948118/orig
  2. Donny Darko 30 April 2023 08:22:57
    Name: Gas Fondital Madeira Solar KRBS MZ 12; Catalog: Heating boilers