Change history for item: Gas Fondital Madeira Solar Compact KBS Z 24

  1. Donny Darko 08 July 2023 05:30:30
    1. Create: Description #3395972
      Value: Type of heating boiler: gas, max. heating power: 24.90 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3395973
      Value: Gas, condensing
    3. Create: Burner #3395974
      Value: Gas
    4. Create: Number of circuits #3395975
      Value: Double-circuit
    5. Create: Thermal power #3395976
      Value: 2.70 - 24.90 kW
    6. Create: Max. thermal load #3395977
      Value: 23.70 kW
    7. Create: The combustion chamber #3395978
      Value: Closed
    8. Create: Efficiency #3395979
      Value: 105.1 %
    9. Create: Control #3395980
      Value: Electronic
    10. Create: Installation #3395981
      Value: Floor
    11. Create: Primary heat exchanger material #3395982
      Value: Stainless steel
    12. Create: Mains voltage #3395983
      Value: Single-phase
    13. Create: Peculiarities #3395984
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3395985
      Value: 170 l
    15. Create: Expansion tank volume #3395986
      Value: 20 l
    16. Create: Equipment #3395987
      Value: Built-in boiler, display
    17. Create: Fuel #3395988
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3395989
      Value: 2.51 cu. m/hour
    19. Create: LPG consumption #3395990
      Value: 1.84 kg/hour
    20. Create: Nominal pressure of natural gas #3395991
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3395992
      Value: 37 mbar
    22. Create: Max. coolant temperature #3395993
      Value: 78 °С
    23. Create: Max. temperature in the DHW circuit #3395994
      Value: 57 °C
    24. Create: Hot water capacity at t 30°C #3395995
      Value: 13.4 l/min
    25. Create: Max. water pressure in the DHW circuit #3395996
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3395997
      Value: 3 bar
    27. Create: Gas connection #3395998
      Value: 1/2"
    28. Create: Heating circuit connection #3395999
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3396000
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3396001
      Value: 60/100 mm and 80/125 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3396002
      Value: Yes
    32. Create: Dimensions WxHxD #3396003
      Value: 600x1857x645mm
    33. Create: Weight #3396004
      Value: 186 kg
    34. Create: Additional Information #3396005
      Value: Coil; expansion tank of the solar circuit - 12 l; solar circuit pump; 3 built-in sets: two sets of low temperature zone and one set of high temperature zone
    35. Create: Image #6321123
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2286871329543497027/orig
    36. Create: Preview image #6321124
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2286871329543497027/orig
  2. Donny Darko 30 April 2023 08:22:52
    Name: Gas Fondital Madeira Solar Compact KBS Z 24; Catalog: Heating boilers