Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:30:30
Create:
Description #3395972
Value: Type of heating boiler: gas, max. heating power: 24.90 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3395973
Value: Gas, condensing
Create:
Burner #3395974
Value: Gas
Create:
Number of circuits #3395975
Value: Double-circuit
Create:
Thermal power #3395976
Value: 2.70 - 24.90 kW
Create:
Max. thermal load #3395977
Value: 23.70 kW
Create:
The combustion chamber #3395978
Value: Closed
Create:
Efficiency #3395979
Value: 105.1 %
Create:
Control #3395980
Value: Electronic
Create:
Installation #3395981
Value: Floor
Create:
Primary heat exchanger material #3395982
Value: Stainless steel
Create:
Mains voltage #3395983
Value: Single-phase
Create:
Peculiarities #3395984
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3395985
Value: 170 l
Create:
Expansion tank volume #3395986
Value: 20 l
Create:
Equipment #3395987
Value: Built-in boiler, display
Create:
Fuel #3395988
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3395989
Value: 2.51 cu. m/hour
Create:
LPG consumption #3395990
Value: 1.84 kg/hour
Create:
Nominal pressure of natural gas #3395991
Value: 20 mbar
Create:
Permissible LPG pressure #3395992
Value: 37 mbar
Create:
Max. coolant temperature #3395993
Value: 78 °С
Create:
Max. temperature in the DHW circuit #3395994
Value: 57 °C
Create:
Hot water capacity at t 30°C #3395995
Value: 13.4 l/min
Create:
Max. water pressure in the DHW circuit #3395996
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3395997
Value: 3 bar
Create:
Gas connection #3395998
Value: 1/2"
Create:
Heating circuit connection #3395999
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3396000
Value: 3/4"
Create:
Coaxial chimney diameter #3396001
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3396002
Value: Yes
Create:
Dimensions WxHxD #3396003
Value: 600x1857x645mm
Create:
Weight #3396004
Value: 186 kg
Create:
Additional Information #3396005
Value: Coil; expansion tank of the solar circuit - 12 l; solar circuit pump; 3 built-in sets: two sets of low temperature zone and one set of high temperature zone
Create:
Image #6321123
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2286871329543497027/orig
Create:
Preview image #6321124
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2286871329543497027/orig
Donny Darko 30 April 2023 08:22:52
Name: Gas Fondital Madeira Solar Compact KBS Z 24; Catalog: Heating boilers