Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:30:23
Create:
Description #3395902
Value: Type of heating boiler: gas, max. heating power: 32.30 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3395903
Value: Gas, condensing
Create:
Burner #3395904
Value: Gas
Create:
Number of circuits #3395905
Value: Double-circuit
Create:
Thermal power #3395906
Value: 3.90 - 32.30 kW
Create:
Max. thermal load #3395907
Value: 30.40 kW
Create:
The combustion chamber #3395908
Value: Closed
Create:
Efficiency #3395909
Value: 106.2 %
Create:
Control #3395910
Value: Electronic
Create:
Installation #3395911
Value: Floor
Create:
Primary heat exchanger material #3395912
Value: Stainless steel
Create:
Secondary heat exchanger material #3395913
Value: Stainless steel
Create:
Mains voltage #3395914
Value: Single-phase
Create:
Peculiarities #3395915
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3395916
Value: 170 l
Create:
Expansion tank volume #3395917
Value: 20 l
Create:
Equipment #3395918
Value: Built-in boiler, display
Create:
Fuel #3395919
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3395920
Value: 3.22 cu. m/hour
Create:
LPG consumption #3395921
Value: 2.36 kg/h
Create:
Nominal pressure of natural gas #3395922
Value: 20 mbar
Create:
Permissible LPG pressure #3395923
Value: 37 mbar
Create:
Max. coolant temperature #3395924
Value: 78 °С
Create:
Max. temperature in the DHW circuit #3395925
Value: 57 °C
Create:
Hot water capacity at t 30°C #3395926
Value: 16.2 l/min
Create:
Max. water pressure in the DHW circuit #3395927
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3395928
Value: 3 bar
Create:
Gas connection #3395929
Value: 1/2"
Create:
Heating circuit connection #3395930
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3395931
Value: 3/4"
Create:
Coaxial chimney diameter #3395932
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3395933
Value: Yes
Create:
Dimensions WxHxD #3395934
Value: 600x1857x645mm
Create:
Weight #3395935
Value: 194 kg
Create:
Additional Information #3395936
Value: Coil; expansion tank of the solar circuit - 12 l; solar circuit pump
Create:
Image #6321119
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2286871329543497027/orig
Create:
Preview image #6321120
URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2286871329543497027/orig
Donny Darko 30 April 2023 08:22:52
Name: Gas Fondital Madeira Solar Compact KBS 32; Catalog: Heating boilers