Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:30:14
Create:
Description #3395833
Value: Type of heating boiler: gas, max. heating power: 28.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3395834
Value: Gas, convection
Create:
Burner #3395835
Value: Gas
Create:
Number of circuits #3395836
Value: Double-circuit
Create:
Thermal power #3395837
Value: 12.30 - 28.60 kW
Create:
Max. thermal load #3395838
Value: 30.50 kW
Create:
The combustion chamber #3395839
Value: Closed
Create:
Efficiency #3395840
Value: 93.7 %
Create:
Control #3395841
Value: Electronic
Create:
Installation #3395842
Value: Wall-mounted
Create:
Primary heat exchanger material #3395843
Value: Copper
Create:
Secondary heat exchanger material #3395844
Value: Stainless steel
Create:
Mains voltage #3395845
Value: Single-phase
Create:
Peculiarities #3395846
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3395847
Value: 8 l
Create:
Fuel #3395848
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3395849
Value: 3.23 cu. m/hour
Create:
LPG consumption #3395850
Value: 2.4 kg/hour
Create:
Nominal pressure of natural gas #3395851
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3395852
Value: 37 mbar
Create:
Heat carrier temperature #3395853
Value: 35 - 83 °С
Create:
Temperature in the DHW circuit #3395854
Value: 35 - 62 °С
Create:
Hot water capacity at t 25°C #3395855
Value: 16.4 l/min
Create:
Hot water capacity at t 30°C #3395856
Value: 13.7 l/min
Create:
Hot water capacity at t 35°C #3395857
Value: 11.4 l/min
Create:
Hot water capacity at t 40°C #3395858
Value: 10.2 l/min
Create:
Hot water capacity at t 45°C #3395859
Value: 9.1 l/min
Create:
Max. water pressure in the heating circuit #3395860
Value: 3 bar
Create:
Gas connection #3395861
Value: 1/2"
Create:
Heating circuit connection #3395862
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3395863
Value: 1/2"
Create:
Coaxial chimney diameter #3395864
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3395865
Value: Yes
Create:
Dimensions WxHxD #3395866
Value: 450x750x325mm
Create:
Weight #3395867
Value: 41 kg
Create:
Image #6321115
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8148534239460835078/orig
Create:
Preview image #6321116
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8148534239460835078/orig
Donny Darko 30 April 2023 08:22:51
Name: Gas Fondital Tahiti Dual CTFS 28 28.6 kW double-circuit; Catalog: Heating boilers