Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:30:06
Create:
Description #3395764
Value: Type of heating boiler: gas, max. heating power: 23.77 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3395765
Value: Gas, convection
Create:
Burner #3395766
Value: Gas
Create:
Number of circuits #3395767
Value: Double-circuit
Create:
Thermal power #3395768
Value: 9.90 - 23.77 kW
Create:
Max. thermal load #3395769
Value: 25.50 kW
Create:
The combustion chamber #3395770
Value: Closed
Create:
Efficiency #3395771
Value: 93.2 %
Create:
Control #3395772
Value: Electronic
Create:
Installation #3395773
Value: Wall-mounted
Create:
Primary heat exchanger material #3395774
Value: Copper
Create:
Secondary heat exchanger material #3395775
Value: Stainless steel
Create:
Mains voltage #3395776
Value: Single-phase
Create:
Peculiarities #3395777
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3395778
Value: 8 l
Create:
Fuel #3395779
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3395780
Value: 2.7 cu. m/hour
Create:
LPG consumption #3395781
Value: 2.01 kg/h
Create:
Nominal pressure of natural gas #3395782
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3395783
Value: 37 mbar
Create:
Heat carrier temperature #3395784
Value: 35 - 83 °С
Create:
Temperature in the DHW circuit #3395785
Value: 35 - 62 °С
Create:
Hot water capacity at t 25°C #3395786
Value: 13.6 l/min
Create:
Hot water capacity at t 30°C #3395787
Value: 11.4 l/min
Create:
Hot water capacity at t 35°C #3395788
Value: 9.7 l/min
Create:
Hot water capacity at t 40°C #3395789
Value: 8.6 l/min
Create:
Hot water capacity at t 45°C #3395790
Value: 7.6 l/min
Create:
Max. water pressure in the heating circuit #3395791
Value: 3 bar
Create:
Gas connection #3395792
Value: 1/2"
Create:
Heating circuit connection #3395793
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3395794
Value: 1/2"
Create:
Coaxial chimney diameter #3395795
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3395796
Value: Yes
Create:
Dimensions WxHxD #3395797
Value: 450x750x325mm
Create:
Weight #3395798
Value: 40.3 kg
Create:
Image #6321111
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8148534239460835078/orig
Create:
Preview image #6321112
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8148534239460835078/orig
Donny Darko 30 April 2023 08:22:51
Name: Gas Fondital Tahiti Dual CTFS 24 23.77 kW double-circuit; Catalog: Heating boilers