Description #3395205
Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3395206
Value: Gas, convection
Create:
Burner #3395207
Value: Gas
Create:
Number of circuits #3395208
Value: Double-circuit
Create:
Thermal power #3395209
Value: 11.10 - 23.70 kW
Create:
Max. thermal load #3395210
Value: 25.50 kW
Create:
The combustion chamber #3395211
Value: Closed
Create:
Efficiency #3395212
Value: 93 %
Create:
Control #3395213
Value: Electronic
Create:
Installation #3395214
Value: Wall-mounted
Create:
Primary heat exchanger material #3395215
Value: Copper
Create:
Mains voltage #3395216
Value: Single-phase
Create:
Peculiarities #3395217
Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, external control connector, thermometer, water filter
Create:
Expansion tank volume #3395218
Value: 7 l
Create:
Equipment #3395219
Value: Display, room thermostat
Create:
Fuel #3395220
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3395221
Value: 2.7 cu. m/hour
Create:
LPG consumption #3395222
Value: 2.01 kg/h
Create:
Nominal pressure of natural gas #3395223
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3395224
Value: 37 mbar
Create:
Max. coolant temperature #3395225
Value: 83 °С
Create:
Max. temperature in the DHW circuit #3395226
Value: 62 °С
Create:
Hot water capacity at t 25°C #3395227
Value: 13.9 l/min
Create:
Hot water capacity at t 30°C #3395228
Value: 11.6 l/min
Create:
Hot water capacity at t 35°C #3395229
Value: 9.9 l/min
Create:
Hot water capacity at t 40°C #3395230
Value: 8.7 l/min
Create:
Hot water capacity at t 45°C #3395231
Value: 7.7 l/min
Create:
Max. water pressure in the DHW circuit #3395232
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3395233
Value: 3 bar
Create:
Gas connection #3395234
Value: 1/2"
Create:
Heating circuit connection #3395235
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3395236
Value: 1/2"
Create:
Coaxial chimney diameter #3395237
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3395238
Value: Yes
Create:
Dimensions WxHxD #3395239
Value: 420x750x315 mm
Create:
Weight #3395240
Value: 33.89 kg
Create:
Additional Information #3395241
Value: The ability to control 3 types of solar collector systems
Create:
Image #6321039
URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id2136952974025086.jpeg/orig
Create:
Image #6321040
URL: https://avatars.mds.yandex.net/get-mpic/6458782/img_id218150504025588078.jpeg/orig
Create:
Image #6321041
URL: https://avatars.mds.yandex.net/get-mpic/5238263/img_id2369057278774650129.jpeg/orig
Create:
Image #6321042
URL: https://avatars.mds.yandex.net/get-mpic/5345452/img_id3716050980595195042.jpeg/orig
Create:
Preview image #6321043
URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id2136952974025086.jpeg/orig
Donny Darko 30 April 2023 08:22:45
Name: Gas Fondital Formentera CTFS 24; Catalog: Heating boilers