Change history for item: Gas Fondital Itaca CTFS 32

  1. Donny Darko 08 July 2023 05:28:32
    1. Create: Description #3395093
      Value: Type of heating boiler: gas, max. heating power: 30.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3395094
      Value: Gas, convection
    3. Create: Burner #3395095
      Value: Gas
    4. Create: Number of circuits #3395096
      Value: Double-circuit
    5. Create: Thermal power #3395097
      Value: 14.30 - 30.80 kW
    6. Create: The combustion chamber #3395098
      Value: Closed
    7. Create: Efficiency #3395099
      Value: 93.4 %
    8. Create: Control #3395100
      Value: Electronic
    9. Create: Installation #3395101
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3395102
      Value: Copper
    11. Create: Mains voltage #3395103
      Value: Single-phase
    12. Create: Peculiarities #3395104
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3395105
      Value: 10 l
    14. Create: Equipment #3395106
      Value: Display
    15. Create: Fuel #3395107
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3395108
      Value: 3.49 cu. m/hour
    17. Create: LPG consumption #3395109
      Value: 2.6 kg/hour
    18. Create: Nominal pressure of natural gas #3395110
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3395111
      Value: 37 mbar
    20. Create: Heat carrier temperature #3395112
      Value: 35 - 83 °С
    21. Create: Temperature in the DHW circuit #3395113
      Value: 35 - 62 °С
    22. Create: Hot water capacity at t 25°C #3395114
      Value: 18 l/min
    23. Create: Hot water capacity at t 30°C #3395115
      Value: 15.1 l/min
    24. Create: Hot water capacity at t 35°C #3395116
      Value: 12.9 l/min
    25. Create: Hot water capacity at t 40°C #3395117
      Value: 11.3 l/min
    26. Create: Hot water capacity at t 45°C #3395118
      Value: 10.1 l/min
    27. Create: Max. water pressure in the DHW circuit #3395119
      Value: 6 bar
    28. Create: Max. water pressure in the heating circuit #3395120
      Value: 3 bar
    29. Create: Heating circuit connection #3395121
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3395122
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3395123
      Value: 80/100 mm
    32. Create: Connection of a separate chimney diameter 80 mm #3395124
      Value: Yes
    33. Create: Dimensions WxHxD #3395125
      Value: 420x750x315 mm
    34. Create: Weight #3395126
      Value: 36 kg
    35. Create: Image #6321028
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2694477220589533982/orig
    36. Create: Image #6321029
      URL: https://avatars.mds.yandex.net/get-mpic/1808939/img_id3190379468004507338.png/orig
    37. Create: Preview image #6321030
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2694477220589533982/orig
  2. Donny Darko 30 April 2023 08:22:44
    Name: Gas Fondital Itaca CTFS 32; Catalog: Heating boilers