Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:26:37
Create:
Width #32652
Value: 440
Create:
Height #32653
Value: 742
Create:
Description #3394351
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3394352
Value: Gas
Create:
Number of circuits #3394353
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3394354
Value: Convection
Create:
The principle of operation of a solid fuel boiler #3394355
Value: A gas boiler
Create:
Combustion chamber type #3394356
Value: Closed
Create:
Primary heat exchanger material #3394357
Value: Copper
Create:
Accommodation #3394358
Value: Wall
Create:
Non-volatile #3394359
Value: There is
Create:
Power type #3394360
Value: Single-phase
Create:
Control #3394361
Value: Electronic
Create:
Equipment #3394362
Value: Display
Create:
Functions #3394363
Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation
Create:
Minimum heat output #3394364
Value: 9.2 kW
Create:
Max. thermal power #3394365
Value: 24 kW
Create:
Maximum thermal load #3394366
Value: 24 kW
Create:
Efficiency #3394367
Value: 93 %
Create:
Heated area #3394368
Value: 240 m²
Create:
Maximum water pressure in the heating circuit #3394369
Value: 3 bar
Create:
Minimum heating medium temperature #3394370
Value: 35°C
Create:
Maximum coolant temperature #3394371
Value: 70°C
Create:
Expansion tank volume #3394372
Value: 6 l
Create:
Gas connection #3394373
Value: 1/2"
Create:
Heating circuit connection #3394374
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3394375
Value: 1/2"
Create:
Coaxial chimney diameter #3394376
Value: 60/100 mm
Create:
Separate chimney 80x80 mm #3394377
Value: There is
Create:
Burner #3394378
Value: Gas
Create:
Secondary heat exchanger material #3394379
Value: Stainless steel
Create:
Maximum water pressure in the DHW circuit #3394380
Value: 8 bar
Create:
Recommended fuel #3394381
Value: Liquefied gas
Create:
Fuel #3394382
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3394383
Value: 2.73 kg/h
Create:
Hot water capacity at t 25°C #3394384
Value: 13.6 l/min
Create:
Hot water capacity at t 30°C #3394385
Value: 11.3 l/min
Create:
Depth #3394386
Value: 235 mm
Create:
Weight #3394387
Value: 30 kg
Create:
Image #6320900
URL: https://avatars.mds.yandex.net/get-mpic/1927699/img_id356848719969958211.jpeg/orig
Create:
Image #6320901
URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id8114498797435604491.jpeg/orig
Create:
Image #6320902
URL: https://avatars.mds.yandex.net/get-mpic/5236090/img_id3991693627749357305.jpeg/orig
Create:
Image #6320903
URL: https://avatars.mds.yandex.net/get-mpic/4742551/img_id4339866282820019556.jpeg/orig
Create:
Image #6320904
URL: https://avatars.mds.yandex.net/get-mpic/6212300/img_id3731627958881612478.jpeg/orig
Create:
Image #6320905
URL: https://avatars.mds.yandex.net/get-mpic/1336510/img_id1486310830565172037.jpeg/orig
Create:
Image #6320906
URL: https://avatars.mds.yandex.net/get-mpic/5262552/img_id3309266330432307301.jpeg/orig
Create:
Preview image #6320907
URL: https://avatars.mds.yandex.net/get-mpic/1927699/img_id356848719969958211.jpeg/orig
Donny Darko 30 April 2023 08:22:36
Name: Gas wall FERROLI Vitabel F24 with two heat exchangers; Catalog: Heating boilers