Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:25:19
Create:
Description #3394073
Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3394074
Value: Gas, convection
Create:
Burner #3394075
Value: Gas
Create:
Number of circuits #3394076
Value: Double-circuit
Create:
Thermal power #3394077
Value: 8.40 - 24 kW
Create:
Thermal load #3394078
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3394079
Value: Closed
Create:
Efficiency #3394080
Value: 93.1 %
Create:
Control #3394081
Value: Electronic
Create:
Installation #3394082
Value: Wall-mounted
Create:
Primary heat exchanger material #3394083
Value: Copper
Create:
Secondary heat exchanger material #3394084
Value: Stainless steel
Create:
Mains voltage #3394085
Value: Single-phase
Create:
Peculiarities #3394086
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer, water filter
Create:
Expansion tank volume #3394087
Value: 6 l
Create:
Equipment #3394088
Value: Display
Create:
Fuel #3394089
Value: Natural gas
Create:
Natural gas consumption #3394090
Value: 2.73 cu. m/hour
Create:
LPG consumption #3394091
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3394092
Value: 3 - 20 mbar
Create:
Permissible LPG pressure #3394093
Value: 37 mbar
Create:
Heat carrier temperature #3394094
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3394095
Value: 35 - 55 °С
Create:
Hot water capacity at t 25°C #3394096
Value: 13.6 l/min
Create:
Hot water capacity at t 30°C #3394097
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3394098
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3394099
Value: 3 bar
Create:
Gas connection #3394100
Value: 1/2"
Create:
Heating circuit connection #3394101
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3394102
Value: 1/2"
Create:
Coaxial chimney diameter #3394103
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3394104
Value: Yes
Create:
Dimensions WxHxD #3394105
Value: 440x740x235mm
Create:
Weight #3394106
Value: 30 kg
Create:
Image #6320740
URL: https://avatars.mds.yandex.net/get-mpic/4338525/img_id5066981252468099806.png/orig
Create:
Image #6320741
URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id7632517984911401209.png/orig
Create:
Image #6320742
URL: https://avatars.mds.yandex.net/get-mpic/1571888/img_id8219464904416234626.jpeg/orig
Create:
Image #6320743
URL: https://avatars.mds.yandex.net/get-mpic/4415357/img_id7483766764262533563.png/orig
Create:
Image #6320744
URL: https://avatars.mds.yandex.net/get-mpic/1884605/img_id4184807759135218673.jpeg/orig
Create:
Image #6320745
URL: https://avatars.mds.yandex.net/get-mpic/1901647/img_id8068474549331462344.jpeg/orig
Create:
Image #6320746
URL: https://avatars.mds.yandex.net/get-mpic/5236698/img_id8794962050721865360.jpeg/orig
Create:
Preview image #6320747
URL: https://avatars.mds.yandex.net/get-mpic/4338525/img_id5066981252468099806.png/orig
Donny Darko 30 April 2023 08:22:31
Name: Gas Ferroli Divabel F24, double-circuit; Catalog: Heating boilers