Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:25:14
Create:
Description #3394040
Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3394041
Value: Gas, convection
Create:
Burner #3394042
Value: Gas
Create:
Number of circuits #3394043
Value: Double-circuit
Create:
Thermal power #3394044
Value: 8.40 - 18 kW
Create:
The combustion chamber #3394045
Value: Closed
Create:
Efficiency #3394046
Value: 92.4 %
Create:
Control #3394047
Value: Electronic
Create:
Installation #3394048
Value: Wall-mounted
Create:
Primary heat exchanger material #3394049
Value: Copper
Create:
Secondary heat exchanger material #3394050
Value: Stainless steel
Create:
Mains voltage #3394051
Value: Single-phase
Create:
Peculiarities #3394052
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve
Create:
Expansion tank volume #3394053
Value: 6 l
Create:
Equipment #3394054
Value: Display
Create:
Fuel #3394055
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3394056
Value: 1.9 cu. m/hour
Create:
LPG consumption #3394057
Value: 1.5 kg/hour
Create:
Nominal pressure of natural gas #3394058
Value: 20 mbar
Create:
Permissible LPG pressure #3394059
Value: 37 mbar
Create:
Heat carrier temperature #3394060
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3394061
Value: 35 - 55 °С
Create:
Hot water capacity at t 25°C #3394062
Value: 13.6 l/min
Create:
Hot water capacity at t 30°C #3394063
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3394064
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3394065
Value: 3 bar
Create:
Gas connection #3394066
Value: 1/2"
Create:
Heating circuit connection #3394067
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3394068
Value: 1/2"
Create:
Coaxial chimney diameter #3394069
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3394070
Value: Yes
Create:
Dimensions WxHxD #3394071
Value: 440x742x235 mm
Create:
Weight #3394072
Value: 30 kg
Create:
Image #6320731
URL: https://avatars.mds.yandex.net/get-mpic/5238586/img_id7571193034890083611.jpeg/orig
Create:
Image #6320732
URL: https://avatars.mds.yandex.net/get-mpic/3749045/img_id121237791919323672.jpeg/orig
Create:
Image #6320733
URL: https://avatars.mds.yandex.net/get-mpic/5252617/img_id3242699285745762865.jpeg/orig
Create:
Image #6320734
URL: https://avatars.mds.yandex.net/get-mpic/5297001/img_id3038567024603792748.jpeg/orig
Create:
Image #6320735
URL: https://avatars.mds.yandex.net/get-mpic/5222613/img_id1468449695468206696.png/orig
Create:
Image #6320736
URL: https://avatars.mds.yandex.net/get-mpic/5234569/img_id8045016746235084524.png/orig
Create:
Image #6320737
URL: https://avatars.mds.yandex.net/get-mpic/6257919/img_id9119170925587605311.jpeg/orig
Create:
Image #6320738
URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id9082514978873032945.jpeg/orig
Create:
Preview image #6320739
URL: https://avatars.mds.yandex.net/get-mpic/5238586/img_id7571193034890083611.jpeg/orig
Donny Darko 30 April 2023 08:22:31
Name: Convection gas Ferroli Divabel F 18, 18 kW, double-circuit; Catalog: Heating boilers