Change history for item: Gas Ferroli Divabel F10 double-circuit

  1. Donny Darko 08 July 2023 05:22:26
    1. Create: Description #3393303
      Value: Type of heating boiler: gas, max. thermal power: 10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3393304
      Value: Gas, convection
    3. Create: Burner #3393305
      Value: Gas
    4. Create: Number of circuits #3393306
      Value: Double-circuit
    5. Create: Thermal power #3393307
      Value: 8.40 - 10 kW
    6. Create: The combustion chamber #3393308
      Value: Closed
    7. Create: Efficiency #3393309
      Value: 91.3 %
    8. Create: Control #3393310
      Value: Electronic
    9. Create: Installation #3393311
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3393312
      Value: Copper
    11. Create: Secondary heat exchanger material #3393313
      Value: Stainless steel
    12. Create: Mains voltage #3393314
      Value: Single-phase
    13. Create: Peculiarities #3393315
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve
    14. Create: Expansion tank volume #3393316
      Value: 6 l
    15. Create: Equipment #3393317
      Value: Built-in exhaust fan, display
    16. Create: Fuel #3393318
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3393319
      Value: 1.3 cu. m/hour
    18. Create: LPG consumption #3393320
      Value: 1 kg/hour
    19. Create: Nominal pressure of natural gas #3393321
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3393322
      Value: 37 mbar
    21. Create: Heat carrier temperature #3393323
      Value: 30 - 90 °С
    22. Create: Temperature in the DHW circuit #3393324
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 25°C #3393325
      Value: 13.6 l/min
    24. Create: Hot water capacity at t 30°C #3393326
      Value: 11.3 l/min
    25. Create: Max. water pressure in the DHW circuit #3393327
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3393328
      Value: 3 bar
    27. Create: Gas connection #3393329
      Value: 1/2"
    28. Create: Heating circuit connection #3393330
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3393331
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3393332
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3393333
      Value: Yes
    32. Create: Dimensions WxHxD #3393334
      Value: 440x742x235 mm
    33. Create: Weight #3393335
      Value: 30 kg
    34. Create: Image #6320486
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id8803380269130665274.jpeg/orig
    35. Create: Image #6320487
      URL: https://avatars.mds.yandex.net/get-mpic/5270077/img_id7171623854299329374.jpeg/orig
    36. Create: Image #6320488
      URL: https://avatars.mds.yandex.net/get-mpic/4575382/img_id5441046901873672498.jpeg/orig
    37. Create: Image #6320489
      URL: https://avatars.mds.yandex.net/get-mpic/4937117/img_id45122194997093975.jpeg/orig
    38. Create: Image #6320490
      URL: https://avatars.mds.yandex.net/get-mpic/1961245/img_id840023531693723958.png/orig
    39. Create: Image #6320491
      URL: https://avatars.mds.yandex.net/get-mpic/1866164/img_id713254459663148180.jpeg/orig
    40. Create: Preview image #6320492
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id8803380269130665274.jpeg/orig
  2. Donny Darko 30 April 2023 08:22:20
    Name: Gas Ferroli Divabel F10 double-circuit; Catalog: Heating boilers