Change history for item: Gas Ferroli Force W 60 single-circuit

  1. Donny Darko 08 July 2023 05:21:37
    1. Create: Description #3392981
      Value: Type of heating boiler: gas, max. heating power: 60.80 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3392982
      Value: Gas, condensing
    3. Create: Burner #3392983
      Value: Gas
    4. Create: Number of circuits #3392984
      Value: Single-loop
    5. Create: Thermal power #3392985
      Value: 14.70 - 60.80 kW
    6. Create: The combustion chamber #3392986
      Value: Closed
    7. Create: Efficiency #3392987
      Value: 109 %
    8. Create: Control #3392988
      Value: Electronic
    9. Create: Installation #3392989
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3392990
      Value: Aluminum
    11. Create: Mains voltage #3392991
      Value: Single-phase
    12. Create: Peculiarities #3392992
      Value: Pressure gauge, safety valve
    13. Create: Equipment #3392993
      Value: Display
    14. Create: Fuel #3392994
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3392995
      Value: 6.14 cu. m/hour
    16. Create: LPG consumption #3392996
      Value: 4.51 kg/h
    17. Create: Nominal pressure of natural gas #3392997
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3392998
      Value: 37 mbar
    19. Create: Max. coolant temperature #3392999
      Value: 95 °С
    20. Create: Max. water pressure in the heating circuit #3393000
      Value: 6 bar
    21. Create: Gas connection #3393001
      Value: 1"
    22. Create: Heating circuit connection #3393002
      Value: 1¼
    23. Create: Chimney diameter #3393003
      Value: 100 mm
    24. Create: Dimensions WxHxD #3393004
      Value: 610x904x460 mm
    25. Create: Weight #3393005
      Value: 54 kg
    26. Create: Additional Information #3393006
      Value: Rated heat output 80/60 °С min-max - 14.7-57 kW; rated thermal power 50/30 °C min-max - 16.3-60.8 kW
    27. Create: Image #6320424
      URL: https://avatars.mds.yandex.net/get-mpic/1912364/img_id6491036749780933489.jpeg/orig
    28. Create: Preview image #6320425
      URL: https://avatars.mds.yandex.net/get-mpic/1912364/img_id6491036749780933489.jpeg/orig
  2. Donny Darko 30 April 2023 08:22:17
    Name: Gas Ferroli Force W 60 single-circuit; Catalog: Heating boilers