Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3392391
Value: Gas, convection
Create:
Burner #3392392
Value: Gas
Create:
Number of circuits #3392393
Value: Double-circuit
Create:
Thermal power #3392394
Value: 8.30 - 16 kW
Create:
Thermal load #3392395
Value: 9.20 - 18.40 kW
Create:
The combustion chamber #3392396
Value: Closed
Create:
Heated area #3392397
Value: 160 sq.m
Create:
Efficiency #3392398
Value: 92.5 %
Create:
Control #3392399
Value: Electronic
Create:
Installation #3392400
Value: Wall-mounted
Create:
Primary heat exchanger material #3392401
Value: Copper
Create:
Secondary heat exchanger material #3392402
Value: Stainless steel
Create:
Mains voltage #3392403
Value: Single-phase
Create:
Peculiarities #3392404
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3392405
Value: 6 l
Create:
Equipment #3392406
Value: Display
Create:
Fuel #3392407
Value: Natural gas
Create:
Natural gas consumption #3392408
Value: 1.86 cu. m/hour
Create:
LPG consumption #3392409
Value: 1.34 kg/hour
Create:
Nominal pressure of natural gas #3392410
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3392411
Value: 37 mbar
Create:
Heat carrier temperature #3392412
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3392413
Value: 35 - 55 °С
Create:
Hot water capacity at t 25°C #3392414
Value: 13.6 l/min
Create:
Hot water capacity at t 30°C #3392415
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3392416
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3392417
Value: 3 bar
Create:
Gas connection #3392418
Value: 1/2"
Create:
Heating circuit connection #3392419
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3392420
Value: 1/2"
Create:
Coaxial chimney diameter #3392421
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3392422
Value: Yes
Create:
Dimensions WxHxD #3392423
Value: 440x742x235 mm
Create:
Weight #3392424
Value: 30 kg
Create:
Image #6320287
URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id7210757856941326510.jpeg/orig
Create:
Image #6320288
URL: https://avatars.mds.yandex.net/get-mpic/1912105/img_id2186890094770419061.png/orig
Create:
Image #6320289
URL: https://avatars.mds.yandex.net/get-mpic/4888456/img_id2581274951264662556.jpeg/orig
Create:
Image #6320290
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id4629818236707146416.jpeg/orig
Create:
Preview image #6320291
URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id7210757856941326510.jpeg/orig
Donny Darko 30 April 2023 08:22:10
Name: Gas Ferroli Fortuna F 16 double-circuit; Catalog: Heating boilers