Description #3391442
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3391443
Value: Gas, convection
Create:
Burner #3391444
Value: Gas
Create:
Number of circuits #3391445
Value: Double-circuit
Create:
Thermal power #3391446
Value: 7.20 - 24 kW
Create:
Thermal load #3391447
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3391448
Value: Closed
Create:
Efficiency #3391449
Value: 93 %
Create:
Control #3391450
Value: Electronic
Create:
Installation #3391451
Value: Wall-mounted
Create:
Primary heat exchanger material #3391452
Value: Copper
Create:
Mains voltage #3391453
Value: Single-phase
Create:
Peculiarities #3391454
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3391455
Value: 7 l
Create:
Equipment #3391456
Value: Display
Create:
Fuel #3391457
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3391458
Value: 2.73 cu. m/hour
Create:
LPG consumption #3391459
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3391460
Value: 20 mbar
Create:
Permissible LPG pressure #3391461
Value: 37 mbar
Create:
Heat carrier temperature #3391462
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3391463
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3391464
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3391465
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3391466
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3391467
Value: 3 bar
Create:
Gas connection #3391468
Value: 1/2"
Create:
Heating circuit connection #3391469
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3391470
Value: 1/2"
Create:
Coaxial chimney diameter #3391471
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3391472
Value: Yes
Create:
Dimensions WxHxD #3391473
Value: 400x700x260mm
Create:
Weight #3391474
Value: 32 kg
Create: