Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:16:47
Create:
Description #3390991
Value: Type of heating boiler: gas, max. heating power: 23.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3390992
Value: Gas, convection
Create:
Burner #3390993
Value: Gas
Create:
Number of circuits #3390994
Value: Double-circuit
Create:
Thermal power #3390995
Value: 7 - 23.50 kW
Create:
Thermal load #3390996
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3390997
Value: Open
Create:
Heated area #3390998
Value: 240 sq.m
Create:
Efficiency #3390999
Value: 91 %
Create:
Control #3391000
Value: Electronic
Create:
Installation #3391001
Value: Wall-mounted
Create:
Mains voltage #3391002
Value: Single-phase
Create:
Peculiarities #3391003
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3391004
Value: 25 l
Create:
Expansion tank volume #3391005
Value: 8 l
Create:
Equipment #3391006
Value: Built-in boiler, display
Create:
Fuel #3391007
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3391008
Value: 2.73 cu. m/hour
Create:
LPG consumption #3391009
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3391010
Value: 20 mbar
Create:
Permissible LPG pressure #3391011
Value: 37 mbar
Create:
Heat carrier temperature #3391012
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3391013
Value: 40 - 65 °С
Create:
Hot water capacity at t 30°C #3391014
Value: 14.5 l/min
Create:
Max. water pressure in the DHW circuit #3391015
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3391016
Value: 3 bar
Create:
Gas connection #3391017
Value: 1/2"
Create:
Heating circuit connection #3391018
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3391019
Value: 1/2"
Create:
Chimney diameter #3391020
Value: 131 mm
Create:
Dimensions WxHxD #3391021
Value: 450x780x330 mm
Create:
Weight #3391022
Value: 44 kg
Create:
Image #6320185
URL: https://avatars.mds.yandex.net/get-mpic/1862933/img_id2923756113309194877/orig
Create:
Preview image #6320186
URL: https://avatars.mds.yandex.net/get-mpic/1862933/img_id2923756113309194877/orig
Donny Darko 30 April 2023 08:21:56
Name: Gas Ferroli Divatop ST 24 C 23.5 kW double-circuit; Catalog: Heating boilers