Change history for item: Gas Ferroli Bluehelix 25 K 50

  1. Donny Darko 08 July 2023 05:16:21
    1. Create: Description #3390781
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3390782
      Value: Gas, condensing
    3. Create: Burner #3390783
      Value: Gas
    4. Create: Number of circuits #3390784
      Value: Double-circuit
    5. Create: Thermal power #3390785
      Value: 5.70 - 25 kW
    6. Create: Thermal load #3390786
      Value: 5.80 - 25 kW
    7. Create: The combustion chamber #3390787
      Value: Closed
    8. Create: Efficiency #3390788
      Value: 109 %
    9. Create: Control #3390789
      Value: Electronic
    10. Create: Installation #3390790
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3390791
      Value: Stainless steel
    12. Create: Mains voltage #3390792
      Value: Single-phase
    13. Create: Peculiarities #3390793
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3390794
      Value: 50 l
    15. Create: Expansion tank volume #3390795
      Value: 8 l
    16. Create: Equipment #3390796
      Value: Built-in boiler, display
    17. Create: Fuel #3390797
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3390798
      Value: 2.91 cu. m/hour
    19. Create: LPG consumption #3390799
      Value: 2.14 kg/h
    20. Create: Nominal pressure of natural gas #3390800
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3390801
      Value: 37 mbar
    22. Create: Heat carrier temperature #3390802
      Value: 20 - 90 °C
    23. Create: Temperature in the DHW circuit #3390803
      Value: 10 - 66 °С
    24. Create: Hot water capacity at t 30°C #3390804
      Value: 17.5 l/min
    25. Create: Max. water pressure in the DHW circuit #3390805
      Value: 9 bar
    26. Create: Max. water pressure in the heating circuit #3390806
      Value: 3 bar
    27. Create: Gas connection #3390807
      Value: 1/2"
    28. Create: Heating circuit connection #3390808
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3390809
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3390810
      Value: 60/100 mm
    31. Create: Dimensions WxHxD #3390811
      Value: 600x800x400mm
    32. Create: Weight #3390812
      Value: 56 kg
    33. Create: Image #6320169
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id8971800957977276887/orig
    34. Create: Image #6320170
      URL: https://avatars.mds.yandex.net/get-mpic/5234463/img_id1344467141537985549.png/orig
    35. Create: Image #6320171
      URL: https://avatars.mds.yandex.net/get-mpic/5234200/img_id6610222719136887767.png/orig
    36. Create: Preview image #6320172
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id8971800957977276887/orig
  2. Donny Darko 30 April 2023 08:21:54
    Name: Gas Ferroli Bluehelix 25 K 50; Catalog: Heating boilers