Change history for item: Gas Ferroli Bluehelix Tech 25C

  1. Donny Darko 08 July 2023 05:12:59
    1. Create: Description #3389572
      Value: Type of heating boiler: gas, max. heating power: 24.50 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3389573
      Value: Gas, condensing
    3. Create: Burner #3389574
      Value: Gas
    4. Create: Number of circuits #3389575
      Value: Double-circuit
    5. Create: Thermal power #3389576
      Value: 5.70 - 24.50 kW
    6. Create: Thermal load #3389577
      Value: 5.80 - 25 kW
    7. Create: The combustion chamber #3389578
      Value: Closed
    8. Create: Efficiency #3389579
      Value: 107.5 %
    9. Create: Control #3389580
      Value: Electronic
    10. Create: Installation #3389581
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3389582
      Value: Stainless steel
    12. Create: Mains voltage #3389583
      Value: Single-phase
    13. Create: Peculiarities #3389584
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3389585
      Value: 8 l
    15. Create: Equipment #3389586
      Value: Display
    16. Create: Fuel #3389587
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3389588
      Value: 2.91 cu. m/hour
    18. Create: LPG consumption #3389589
      Value: 2.15 kg/hour
    19. Create: Nominal pressure of natural gas #3389590
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3389591
      Value: 37 mbar
    21. Create: Max. coolant temperature #3389592
      Value: 90 °С
    22. Create: Hot water capacity at t 25°C #3389593
      Value: 15.5 l/min
    23. Create: Hot water capacity at t 30°C #3389594
      Value: 12.9 l/min
    24. Create: Max. water pressure in the DHW circuit #3389595
      Value: 9 bar
    25. Create: Max. water pressure in the heating circuit #3389596
      Value: 3 bar
    26. Create: Coaxial chimney diameter #3389597
      Value: 60/100 mm and 80/125 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3389598
      Value: Yes
    28. Create: Dimensions WxHxD #3389599
      Value: 400x600x320mm
    29. Create: Weight #3389600
      Value: 29 kg
    30. Create: Additional Information #3389601
      Value: Possibility of connection to a system with solar collectors
    31. Create: Image #6319974
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2704935272129231068/orig
    32. Create: Preview image #6319975
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id2704935272129231068/orig
  2. Donny Darko 30 April 2023 08:21:40
    Name: Gas Ferroli Bluehelix Tech 25C; Catalog: Heating boilers