Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:11:37
Create:
Description #3389002
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3389003
Value: Gas, convection
Create:
Burner #3389004
Value: Gas
Create:
Number of circuits #3389005
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3389006
Value: 7.20 - 24 kW
Create:
Thermal load #3389007
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3389008
Value: Closed
Create:
Efficiency #3389009
Value: 93 %
Create:
Control #3389010
Value: Electronic
Create:
Installation #3389011
Value: Wall-mounted
Create:
Primary heat exchanger material #3389012
Value: Copper
Create:
Mains voltage #3389013
Value: Single-phase
Create:
Peculiarities #3389014
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3389015
Value: 7 l
Create:
Equipment #3389016
Value: Display
Create:
Fuel #3389017
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3389018
Value: 2.73 cu. m/hour
Create:
LPG consumption #3389019
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3389020
Value: 20 mbar
Create:
Permissible LPG pressure #3389021
Value: 37 mbar
Create:
Heat carrier temperature #3389022
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3389023
Value: 40 - 50 °С
Create:
Hot water capacity at t 25°C #3389024
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3389025
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3389026
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3389027
Value: 3 bar
Create:
Gas connection #3389028
Value: 1/2"
Create:
Heating circuit connection #3389029
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3389030
Value: 1/2"
Create:
Coaxial chimney diameter #3389031
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3389032
Value: Yes
Create:
Dimensions WxHxD #3389033
Value: 400x700x360mm
Create:
Weight #3389034
Value: 32 kg
Create:
Image #6319930
URL: https://avatars.mds.yandex.net/get-mpic/1417902/img_id6281238069635293366/orig
Create:
Preview image #6319931
URL: https://avatars.mds.yandex.net/get-mpic/1417902/img_id6281238069635293366/orig
Donny Darko 30 April 2023 08:21:33
Name: Gas Ferroli Domitech D F24; Catalog: Heating boilers