Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:11:34
Create:
Description #3388969
Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3388970
Value: Gas, convection
Create:
Burner #3388971
Value: Gas
Create:
Number of circuits #3388972
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3388973
Value: 9.90 - 32 kW
Create:
Thermal load #3388974
Value: 11.50 - 34.40 kW
Create:
The combustion chamber #3388975
Value: Closed
Create:
Efficiency #3388976
Value: 93.1 %
Create:
Control #3388977
Value: Electronic
Create:
Installation #3388978
Value: Wall-mounted
Create:
Primary heat exchanger material #3388979
Value: Copper
Create:
Mains voltage #3388980
Value: Single-phase
Create:
Peculiarities #3388981
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3388982
Value: 10 l
Create:
Equipment #3388983
Value: Display
Create:
Fuel #3388984
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3388985
Value: 3.64 cu. m/hour
Create:
LPG consumption #3388986
Value: 2.69 kg/h
Create:
Nominal pressure of natural gas #3388987
Value: 20 mbar
Create:
Permissible LPG pressure #3388988
Value: 37 mbar
Create:
Heat carrier temperature #3388989
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3388990
Value: 40 - 50 °С
Create:
Hot water capacity at t 25°C #3388991
Value: 18.3 l/min
Create:
Hot water capacity at t 30°C #3388992
Value: 15.2 l/min
Create:
Max. water pressure in the DHW circuit #3388993
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3388994
Value: 3 bar
Create:
Gas connection #3388995
Value: 1/2"
Create:
Heating circuit connection #3388996
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3388997
Value: 1/2"
Create:
Coaxial chimney diameter #3388998
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3388999
Value: Yes
Create:
Dimensions WxHxD #3389000
Value: 400x700x360mm
Create:
Weight #3389001
Value: 38 kg
Create:
Image #6319928
URL: https://avatars.mds.yandex.net/get-mpic/1417902/img_id6281238069635293366/orig
Create:
Preview image #6319929
URL: https://avatars.mds.yandex.net/get-mpic/1417902/img_id6281238069635293366/orig
Donny Darko 30 April 2023 08:21:33
Name: Gas Ferroli Domitech D F32 32 kW double-circuit; Catalog: Heating boilers