Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:11:07
Create:
Description #3388753
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3388754
Value: Gas, convection
Create:
Burner #3388755
Value: Gas
Create:
Number of circuits #3388756
Value: Double-circuit
Create:
Thermal power #3388757
Value: 7.20 - 24 kW
Create:
Thermal load #3388758
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3388759
Value: Closed
Create:
Heated area #3388760
Value: 240 sq.m
Create:
Efficiency #3388761
Value: 93 %
Create:
Control #3388762
Value: Electronic
Create:
Installation #3388763
Value: Wall-mounted
Create:
Primary heat exchanger material #3388764
Value: Copper
Create:
Mains voltage #3388765
Value: Single-phase
Create:
Peculiarities #3388766
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control
Create:
Expansion tank volume #3388767
Value: 8 l
Create:
Fuel #3388768
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3388769
Value: 2.73 cu. m/hour
Create:
LPG consumption #3388770
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3388771
Value: 20 mbar
Create:
Permissible LPG pressure #3388772
Value: 37 mbar
Create:
Heat carrier temperature #3388773
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3388774
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3388775
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3388776
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3388777
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3388778
Value: 3 bar
Create:
Gas connection #3388779
Value: 1/2"
Create:
Heating circuit connection #3388780
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3388781
Value: 1/2"
Create:
Coaxial chimney diameter #3388782
Value: 60/100 mm
Create:
Dimensions WxHxD #3388783
Value: 400x700x330mm
Create:
Weight #3388784
Value: 30 kg
Create:
Image #6319913
URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id8154976759754809632.jpeg/orig
Create:
Image #6319914
URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id6101082576492820907.jpeg/orig
Create:
Preview image #6319915
URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id8154976759754809632.jpeg/orig
Donny Darko 30 April 2023 08:21:31
Name: Gas Ferroli Divaproject F24; Catalog: Heating boilers