Change history for item: Gas Ferroli Domina Pro F16 16 kW double-circuit

  1. Donny Darko 08 July 2023 05:09:10
    1. Create: Description #3388050
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3388051
      Value: Gas, convection
    3. Create: Burner #3388052
      Value: Gas
    4. Create: Number of circuits #3388053
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3388054
      Value: 6.80 - 16 kW
    6. Create: The combustion chamber #3388055
      Value: Closed
    7. Create: Heated area #3388056
      Value: 160 sq.m
    8. Create: Efficiency #3388057
      Value: 93 %
    9. Create: Control #3388058
      Value: Electronic
    10. Create: Installation #3388059
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3388060
      Value: Copper
    12. Create: Mains voltage #3388061
      Value: Single-phase
    13. Create: Peculiarities #3388062
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3388063
      Value: 6 l
    15. Create: Equipment #3388064
      Value: Display
    16. Create: Fuel #3388065
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3388066
      Value: 1.34 cu. m/hour
    18. Create: LPG consumption #3388067
      Value: 1 kg/hour
    19. Create: Nominal pressure of natural gas #3388068
      Value: 5 - 20 mbar
    20. Create: Permissible LPG pressure #3388069
      Value: 37 mbar
    21. Create: Heat carrier temperature #3388070
      Value: 30 - 90 °С
    22. Create: Temperature in the DHW circuit #3388071
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 25°C #3388072
      Value: 11.7 l/min
    24. Create: Hot water capacity at t 30°C #3388073
      Value: 9.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3388074
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3388075
      Value: 3 bar
    27. Create: Gas connection #3388076
      Value: 3/4"
    28. Create: Heating circuit connection #3388077
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3388078
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3388079
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3388080
      Value: Yes
    32. Create: Dimensions WxHxD #3388081
      Value: 350x655x230mm
    33. Create: Weight #3388082
      Value: 26 kg
    34. Create: Image #6319854
      URL: https://avatars.mds.yandex.net/get-mpic/4372959/img_id6929747065583729148.jpeg/orig
    35. Create: Preview image #6319855
      URL: https://avatars.mds.yandex.net/get-mpic/4372959/img_id6929747065583729148.jpeg/orig
  2. Donny Darko 30 April 2023 08:21:23
    Name: Gas Ferroli Domina Pro F16 16 kW double-circuit; Catalog: Heating boilers