      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3387448
      Value: Gas, convection
    3. Create: Burner #3387449
      Value: Gas
    4. Create: Number of circuits #3387450
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3387451
      Value: 7.20 - 16 kW
    6. Create: Thermal load #3387452
      Value: 8.30 - 17.20 kW
    7. Create: The combustion chamber #3387453
      Value: Open
    8. Create: Efficiency #3387454
      Value: 91 %
    9. Create: Control #3387455
      Value: Electronic
    10. Create: Installation #3387456
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3387457
      Value: Copper
    12. Create: Mains voltage #3387458
      Value: Single-phase
    13. Create: Peculiarities #3387459
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
    14. Create: Expansion tank volume #3387460
      Value: 8 l
    15. Create: Fuel #3387461
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3387462
      Value: 1.86 cu. m/hour
    17. Create: LPG consumption #3387463
      Value: 13.8 kg/hour
    18. Create: Nominal pressure of natural gas #3387464
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3387465
      Value: 37 mbar
    20. Create: Heat carrier temperature #3387466
      Value: 30 - 90 °С
    21. Create: Temperature in the DHW circuit #3387467
      Value: 40 - 65 °С
    22. Create: Hot water capacity at t 25°C #3387468
      Value: 11.5 l/min
    23. Create: Hot water capacity at t 30°C #3387469
      Value: 9.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3387470
      Value: 9 bar
    25. Create: Max. water pressure in the heating circuit #3387471
      Value: 3 bar
    26. Create: Gas connection #3387472
      Value: 1/2"
    27. Create: Heating circuit connection #3387473
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3387474
      Value: 1/2"
    29. Create: Chimney diameter #3387475
      Value: 110 mm
    30. Create: Dimensions WxHxD #3387476
      Value: 400x700x230mm
    31. Create: Weight #3387477
      Value: 30 kg
    32. Create: Image #6319791
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id9201643726438895130/orig
    33. Create: Image #6319792
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id1486840246594703320/orig
    34. Create: Preview image #6319793
      URL: https://avatars.mds.yandex.net/get-mpic/1081556/img_id9201643726438895130/orig
  2. Donny Darko 30 April 2023 08:21:16
    Name: Gas Ferroli Domina C 16 N 16 kW double-circuit; Catalog: Heating boilers