Change history for item: Gas Ferroli Arena F10 10 kW double-circuit

  1. Donny Darko 08 July 2023 05:06:54
    1. Create: Description #3387092
      Value: Type of heating boiler: gas, max. thermal power: 10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3387093
      Value: Gas, convection
    3. Create: Burner #3387094
      Value: Gas
    4. Create: Number of circuits #3387095
      Value: Double-circuit
    5. Create: Thermal power #3387096
      Value: 7.20 - 10 kW
    6. Create: The combustion chamber #3387097
      Value: Closed
    7. Create: Efficiency #3387098
      Value: 93 %
    8. Create: Control #3387099
      Value: Electronic
    9. Create: Installation #3387100
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3387101
      Value: Copper
    11. Create: Secondary heat exchanger material #3387102
      Value: Stainless steel
    12. Create: Mains voltage #3387103
      Value: Single-phase
    13. Create: Peculiarities #3387104
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, external control connector, thermometer
    14. Create: Fuel #3387105
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3387106
      Value: 1.32 cu. m/hour
    16. Create: LPG consumption #3387107
      Value: 1 kg/hour
    17. Create: Nominal pressure of natural gas #3387108
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3387109
      Value: 37 mbar
    19. Create: Heat carrier temperature #3387110
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3387111
      Value: 40 - 65 °С
    21. Create: Hot water capacity at t 25°C #3387112
      Value: 13.7 l/min
    22. Create: Hot water capacity at t 30°C #3387113
      Value: 11.4 l/min
    23. Create: Gas connection #3387114
      Value: 1/2"
    24. Create: Heating circuit connection #3387115
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3387116
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3387117
      Value: 60/100 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3387118
      Value: Yes
    28. Create: Dimensions WxHxD #3387119
      Value: 400x700x330mm
    29. Create: Weight #3387120
      Value: 35 kg
    30. Create: Image #6319766
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8192925050005510322/orig
    31. Create: Preview image #6319767
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8192925050005510322/orig
  2. Donny Darko 30 April 2023 08:21:13
    Name: Gas Ferroli Arena F10 10 kW double-circuit; Catalog: Heating boilers