Description #3387030
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3387031
Value: Gas, convection
Create:
Burner #3387032
Value: Gas
Create:
Number of circuits #3387033
Value: Double-circuit
Create:
Thermal power #3387034
Value: 7.20 - 24 kW
Create:
Thermal load #3387035
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3387036
Value: Closed
Create:
Efficiency #3387037
Value: 93 %
Create:
Control #3387038
Value: Electronic
Create:
Installation #3387039
Value: Wall-mounted
Create:
Primary heat exchanger material #3387040
Value: Copper
Create:
Secondary heat exchanger material #3387041
Value: Stainless steel
Create:
Mains voltage #3387042
Value: Single-phase
Create:
Peculiarities #3387043
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
Create:
Expansion tank volume #3387044
Value: 8 l
Create:
Fuel #3387045
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3387046
Value: 2.73 cu. m/hour
Create:
LPG consumption #3387047
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3387048
Value: 20 mbar
Create:
Permissible LPG pressure #3387049
Value: 37 mbar
Create:
Heat carrier temperature #3387050
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3387051
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3387052
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3387053
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3387054
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3387055
Value: 3 bar
Create:
Gas connection #3387056
Value: 1/2"
Create:
Heating circuit connection #3387057
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3387058
Value: 1/2"
Create:
Coaxial chimney diameter #3387059
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3387060
Value: Yes
Create:
Dimensions WxHxD #3387061
Value: 400x700x330mm
Create:
Weight #3387062
Value: 32 kg
Create:
Image #6319762
URL: https://avatars.mds.yandex.net/get-mpic/1246680/img_id4929932800758008546.jpeg/orig
Create:
Preview image #6319763
URL: https://avatars.mds.yandex.net/get-mpic/1246680/img_id4929932800758008546.jpeg/orig
Donny Darko 30 April 2023 08:21:12
Name: Gas Ferroli Arena F24; Catalog: Heating boilers