Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:06:43
Create:
Description #3386997
Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3386998
Value: Gas, convection
Create:
Burner #3386999
Value: Gas
Create:
Number of circuits #3387000
Value: Double-circuit
Create:
Thermal power #3387001
Value: 7.20 - 20 kW
Create:
Thermal load #3387002
Value: 8.30 - 21.50 kW
Create:
The combustion chamber #3387003
Value: Closed
Create:
Efficiency #3387004
Value: 93 %
Create:
Control #3387005
Value: Electronic
Create:
Installation #3387006
Value: Wall-mounted
Create:
Primary heat exchanger material #3387007
Value: Copper
Create:
Secondary heat exchanger material #3387008
Value: Stainless steel
Create:
Mains voltage #3387009
Value: Single-phase
Create:
Peculiarities #3387010
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
Create:
Expansion tank volume #3387011
Value: 8 l
Create:
Fuel #3387012
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3387013
Value: 2.27 cu. m/hour
Create:
LPG consumption #3387014
Value: 1.68 kg/hour
Create:
Nominal pressure of natural gas #3387015
Value: 20 mbar
Create:
Permissible LPG pressure #3387016
Value: 37 mbar
Create:
Heat carrier temperature #3387017
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3387018
Value: 40 - 65 °С
Create:
Hot water capacity at t 25°C #3387019
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3387020
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3387021
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3387022
Value: 3 bar
Create:
Gas connection #3387023
Value: 1/2"
Create:
Heating circuit connection #3387024
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3387025
Value: 1/2"
Create:
Coaxial chimney diameter #3387026
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3387027
Value: Yes
Create:
Dimensions WxHxD #3387028
Value: 400x700x330mm
Create:
Weight #3387029
Value: 32 kg
Create:
Image #6319760
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4308744724900151847/orig
Create:
Preview image #6319761
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4308744724900151847/orig
Donny Darko 30 April 2023 08:21:12
Name: Gas Ferroli Arena F20; Catalog: Heating boilers