Change history for item: Gas Ferroli Domina C 24 N

  1. Donny Darko 08 July 2023 05:05:59
    1. Create: Description #3386654
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3386655
      Value: Gas, convection
    3. Create: Burner #3386656
      Value: Gas
    4. Create: Number of circuits #3386657
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3386658
      Value: 9.70 - 24 kW
    6. Create: Thermal load #3386659
      Value: 11.50 - 25.80 kW
    7. Create: The combustion chamber #3386660
      Value: Open
    8. Create: Control #3386661
      Value: Electronic
    9. Create: Installation #3386662
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3386663
      Value: Copper
    11. Create: Mains voltage #3386664
      Value: Single-phase
    12. Create: Peculiarities #3386665
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
    13. Create: Expansion tank volume #3386666
      Value: 7 l
    14. Create: Fuel #3386667
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3386668
      Value: 2.73 cu. m/hour
    16. Create: LPG consumption #3386669
      Value: 2 kg/hour
    17. Create: Nominal pressure of natural gas #3386670
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3386671
      Value: 37 mbar
    19. Create: Heat carrier temperature #3386672
      Value: 35 - 85 °С
    20. Create: Temperature in the DHW circuit #3386673
      Value: 40 - 55 °С
    21. Create: Hot water capacity at t 25°C #3386674
      Value: 13 l/min
    22. Create: Hot water capacity at t 30°C #3386675
      Value: 11 l/min
    23. Create: Max. water pressure in the DHW circuit #3386676
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3386677
      Value: 3 bar
    25. Create: Gas connection #3386678
      Value: 1/2"
    26. Create: Heating circuit connection #3386679
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3386680
      Value: 1/2"
    28. Create: Chimney diameter #3386681
      Value: 131 mm
    29. Create: Dimensions WxHxD #3386682
      Value: 460x725x270mm
    30. Create: Image #6319681
      URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id6333686472933487088.jpeg/orig
    31. Create: Preview image #6319682
      URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id6333686472933487088.jpeg/orig
  2. Donny Darko 30 April 2023 08:21:08
    Name: Gas Ferroli Domina C 24 N; Catalog: Heating boilers