Value: Type of heating boiler: gas, max. heating power: 40.10 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3386093
Value: Gas, convection
Create:
Burner #3386094
Value: Gas
Create:
Number of circuits #3386095
Value: Double-circuit
Create:
Thermal power #3386096
Value: 17.70 - 40.10 kW
Create:
Thermal load #3386097
Value: 19.70 - 42.90 kW
Create:
The combustion chamber #3386098
Value: Open
Create:
Efficiency #3386099
Value: 93.5 %
Create:
Control #3386100
Value: Electronic
Create:
Installation #3386101
Value: Floor
Create:
Primary heat exchanger material #3386102
Value: Cast iron
Create:
Secondary heat exchanger material #3386103
Value: Stainless steel
Create:
Mains voltage #3386104
Value: Single-phase
Create:
Peculiarities #3386105
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3386106
Value: 130 l
Create:
Expansion tank volume #3386107
Value: 12 l
Create:
Equipment #3386108
Value: Built-in boiler, display
Create:
Fuel #3386109
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3386110
Value: 4.54 cu. m/hour
Create:
LPG consumption #3386111
Value: 3.36 kg/h
Create:
Nominal pressure of natural gas #3386112
Value: 4 - 20 mbar
Create:
Permissible LPG pressure #3386113
Value: 37 mbar
Create:
Heat carrier temperature #3386114
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3386115
Value: 10 - 65 °C
Create:
Hot water capacity at t 30°C #3386116
Value: 14.17 l/min
Create:
Max. water pressure in the DHW circuit #3386117
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3386118
Value: 6 bar
Create:
Gas connection #3386119
Value: 1/2"
Create:
Heating circuit connection #3386120
Value: 3/4"
Create:
Chimney diameter #3386121
Value: 150 mm
Create:
Dimensions WxHxD #3386122
Value: 500x1345x950 mm
Create:
Weight #3386123
Value: 27.5 kg
Create:
Image #6319632
URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5662928057027089723/orig
Create:
Preview image #6319633
URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id5662928057027089723/orig
Donny Darko 30 April 2023 08:21:02
Name: Gas Ferroli Pegasus D 40 KI 130 40.1 kW double-circuit; Catalog: Heating boilers