Change history for item: Gas Ferroli Econcept Tech 25 C 24.6 kW double-circuit

  1. Donny Darko 08 July 2023 05:03:32
    1. Create: Description #3385795
      Value: Type of heating boiler: gas, max. heating power: 24.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3385796
      Value: Gas, condensing
    3. Create: Burner #3385797
      Value: Gas
    4. Create: Number of circuits #3385798
      Value: Double-circuit
    5. Create: Thermal power #3385799
      Value: 5.20 - 24.60 kW
    6. Create: Thermal load #3385800
      Value: 5.30 - 25.20 kW
    7. Create: The combustion chamber #3385801
      Value: Closed
    8. Create: Control #3385802
      Value: Electronic
    9. Create: Installation #3385803
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3385804
      Value: Aluminum
    11. Create: Mains voltage #3385805
      Value: Single-phase
    12. Create: Peculiarities #3385806
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3385807
      Value: 8 l
    14. Create: Equipment #3385808
      Value: Display
    15. Create: Fuel #3385809
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3385810
      Value: 2.86 cu. m/hour
    17. Create: LPG consumption #3385811
      Value: 2.11 kg/h
    18. Create: Nominal pressure of natural gas #3385812
      Value: 20 mbar
    19. Create: Heat carrier temperature #3385813
      Value: 20 - 90 °C
    20. Create: Temperature in the DHW circuit #3385814
      Value: 40 - 55 °С
    21. Create: Hot water capacity at t 25°C #3385815
      Value: 15.2 l/min
    22. Create: Hot water capacity at t 30°C #3385816
      Value: 12.7 l/min
    23. Create: Max. water pressure in the DHW circuit #3385817
      Value: 9 bar
    24. Create: Max. water pressure in the heating circuit #3385818
      Value: 3 bar
    25. Create: Gas connection #3385819
      Value: 1/2"
    26. Create: Heating circuit connection #3385820
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3385821
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3385822
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3385823
      Value: Yes
    30. Create: Dimensions WxHxD #3385824
      Value: 450x700x330 mm
    31. Create: Weight #3385825
      Value: 37 kg
    32. Create: Image #6319592
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id6385914960984890664.jpeg/orig
    33. Create: Preview image #6319593
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id6385914960984890664.jpeg/orig
  2. Donny Darko 30 April 2023 08:20:59
    Name: Gas Ferroli Econcept Tech 25 C 24.6 kW double-circuit; Catalog: Heating boilers