Change history for item: Gas Ferroli Divatop 60 F 32 31 kW double-circuit

  1. Donny Darko 08 July 2023 05:03:16
    1. Create: Description #3385682
      Value: Type of heating boiler: gas, max. thermal power: 31 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3385683
      Value: Gas, convection
    3. Create: Burner #3385684
      Value: Gas
    4. Create: Number of circuits #3385685
      Value: Double-circuit
    5. Create: Thermal power #3385686
      Value: 9.20 - 31 kW
    6. Create: Thermal load #3385687
      Value: 10.70 - 33.30 kW
    7. Create: The combustion chamber #3385688
      Value: Closed
    8. Create: Control #3385689
      Value: Electronic
    9. Create: Installation #3385690
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3385691
      Value: Copper
    11. Create: Mains voltage #3385692
      Value: Single-phase
    12. Create: Peculiarities #3385693
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3385694
      Value: 60 l
    14. Create: Expansion tank volume #3385695
      Value: 10 l
    15. Create: Equipment #3385696
      Value: Built-in boiler, display
    16. Create: Fuel #3385697
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3385698
      Value: 3.52 cu. m/hour
    18. Create: LPG consumption #3385699
      Value: 2.6 kg/hour
    19. Create: Nominal pressure of natural gas #3385700
      Value: 20 mbar
    20. Create: Heat carrier temperature #3385701
      Value: 30 - 85 °С
    21. Create: Temperature in the DHW circuit #3385702
      Value: 10 - 65 °C
    22. Create: Hot water capacity at t 30°C #3385703
      Value: 15.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3385704
      Value: 9 bar
    24. Create: Max. water pressure in the heating circuit #3385705
      Value: 3 bar
    25. Create: Gas connection #3385706
      Value: 1/2"
    26. Create: Heating circuit connection #3385707
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3385708
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3385709
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3385710
      Value: Yes
    30. Create: Dimensions WxHxD #3385711
      Value: 600x800x440mm
    31. Create: Weight #3385712
      Value: 62 kg
    32. Create: Image #6319584
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id3870587128431217999/orig
    33. Create: Preview image #6319585
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id3870587128431217999/orig
  2. Donny Darko 30 April 2023 08:20:57
    Name: Gas Ferroli Divatop 60 F 32 31 kW double-circuit; Catalog: Heating boilers