Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:02:51
Create:
Description #3385485
Value: Type of heating boiler: gas, max. thermal power: 37 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3385486
Value: Gas, convection
Create:
Burner #3385487
Value: Gas
Create:
Number of circuits #3385488
Value: Double-circuit
Create:
Thermal power #3385489
Value: 12.90 - 37 kW
Create:
Thermal load #3385490
Value: 14 - 39.70 kW
Create:
The combustion chamber #3385491
Value: Closed
Create:
Efficiency #3385492
Value: 90.5 %
Create:
Control #3385493
Value: Electronic
Create:
Installation #3385494
Value: Wall-mounted
Create:
Primary heat exchanger material #3385495
Value: Copper
Create:
Mains voltage #3385496
Value: Single-phase
Create:
Peculiarities #3385497
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3385498
Value: 3 l
Create:
Expansion tank volume #3385499
Value: 10 l
Create:
Equipment #3385500
Value: Built-in boiler, display
Create:
Fuel #3385501
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3385502
Value: 4.2 cu. m/hour
Create:
LPG consumption #3385503
Value: 3.1 kg/hour
Create:
Nominal pressure of natural gas #3385504
Value: 20 mbar
Create:
Heat carrier temperature #3385505
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3385506
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3385507
Value: 21.2 l/min
Create:
Hot water capacity at t 30°C #3385508
Value: 17.6 l/min
Create:
Max. water pressure in the DHW circuit #3385509
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3385510
Value: 3 bar
Create:
Gas connection #3385511
Value: 1/2"
Create:
Heating circuit connection #3385512
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3385513
Value: 1/2"
Create:
Coaxial chimney diameter #3385514
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3385515
Value: Yes
Create:
Dimensions WxHxD #3385516
Value: 450x700x340mm
Create:
Weight #3385517
Value: 40 kg
Create:
Image #6319570
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id2458986457451448971/orig
Create:
Preview image #6319571
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id2458986457451448971/orig
Donny Darko 30 April 2023 08:20:55
Name: Gas Ferroli Divatop Micro F 37; Catalog: Heating boilers