Create:
Description #3385452
Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3385453
Value: Gas, convection
Create:
Burner #3385454
Value: Gas
Create:
Number of circuits #3385455
Value: Double-circuit
Create:
Thermal power #3385456
Value: 10.60 - 32 kW
Create:
Thermal load #3385457
Value: 11.50 - 34.40 kW
Create:
The combustion chamber #3385458
Value: Closed
Create:
Efficiency #3385459
Value: 90.5 %
Create:
Control #3385460
Value: Electronic
Create:
Installation #3385461
Value: Wall-mounted
Create:
Primary heat exchanger material #3385462
Value: Copper
Create:
Mains voltage #3385463
Value: Single-phase
Create:
Peculiarities #3385464
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3385465
Value: 3 l
Create:
Expansion tank volume #3385466
Value: 10 l
Create:
Equipment #3385467
Value: Built-in boiler, display
Create:
Fuel #3385468
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3385469
Value: 3.64 cu. m/hour
Create:
LPG consumption #3385470
Value: 2.69 kg/h
Create:
Nominal pressure of natural gas #3385471
Value: 20 mbar
Create:
Heat carrier temperature #3385472
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3385473
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3385474
Value: 18.3 l/min
Create:
Hot water capacity at t 30°C #3385475
Value: 15.2 l/min
Create:
Max. water pressure in the DHW circuit #3385476
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3385477
Value: 3 bar
Create:
Gas connection #3385478
Value: 1/2"
Create:
Heating circuit connection #3385479
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3385480
Value: 1/2"
Create:
Coaxial chimney diameter #3385481
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3385482
Value: Yes
Create:
Dimensions WxHxD #3385483
Value: 450x700x340mm
Create:
Weight #3385484
Value: 36 kg
Create:
Image #6319568
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id2458986457451448971/orig
Create:
Preview image #6319569
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id2458986457451448971/orig
Donny Darko 30 April 2023 08:20:55
Name: Gas Ferroli Divatop Micro F 32; Catalog: Heating boilers