Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:01:12
Create:
Description #3384747
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3384748
Value: Gas, convection
Create:
Burner #3384749
Value: Gas
Create:
Number of circuits #3384750
Value: Double-circuit
Create:
Thermal power #3384751
Value: 7.20 - 24 kW
Create:
Thermal load #3384752
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3384753
Value: Closed
Create:
Efficiency #3384754
Value: 93 %
Create:
Control #3384755
Value: Electronic
Create:
Installation #3384756
Value: Wall-mounted
Create:
Primary heat exchanger material #3384757
Value: Copper
Create:
Mains voltage #3384758
Value: Single-phase
Create:
Peculiarities #3384759
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3384760
Value: 7 l
Create:
Equipment #3384761
Value: Display
Create:
Fuel #3384762
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3384763
Value: 2.73 cu. m/hour
Create:
LPG consumption #3384764
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3384765
Value: 20 mbar
Create:
Permissible LPG pressure #3384766
Value: 37 mbar
Create:
Heat carrier temperature #3384767
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3384768
Value: 40 - 65 °С
Create:
Hot water capacity at t 25°C #3384769
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3384770
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3384771
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3384772
Value: 3 bar
Create:
Gas connection #3384773
Value: 1/2"
Create:
Heating circuit connection #3384774
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3384775
Value: 1/2"
Create:
Coaxial chimney diameter #3384776
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3384777
Value: Yes
Create:
Dimensions WxHxD #3384778
Value: 400x700x230mm
Create:
Weight #3384779
Value: 30 kg
Create:
Additional Information #3384780
Value: Can be connected to a solar installation
Create:
Image #6319522
URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id768975237792125332/orig
Create:
Preview image #6319523
URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id768975237792125332/orig
Donny Darko 30 April 2023 08:20:48
Name: Gas Ferroli Domiproject F 24 D; Catalog: Heating boilers