Change history for item: Gas wall mounted condensing boiler Wolf CGB-100

  1. Donny Darko 07 July 2023 18:18:25
    1. Create: Width #32344
      Value: 565
    2. Create: Height #32345
      Value: 1020
    3. Create: Description #3377466
      Value: Type of heating boiler: gas, max. heating power: 98.80 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    4. Create: Type of heating boiler #3377467
      Value: Gas
    5. Create: Number of circuits #3377468
      Value: Single-loop
    6. Create: The principle of operation of a gas boiler #3377469
      Value: Condensing
    7. Create: The principle of operation of a liquid fuel boiler #3377470
      Value: Condensing
    8. Create: The principle of operation of a solid fuel boiler #3377471
      Value: Classical
    9. Create: Combustion chamber type #3377472
      Value: Closed
    10. Create: Accommodation #3377473
      Value: Wall
    11. Create: Non-volatile #3377474
      Value: There is
    12. Create: Power type #3377475
      Value: Single-phase
    13. Create: Control #3377476
      Value: Electronic
    14. Create: Equipment #3377477
      Value: Display
    15. Create: Minimum heat output #3377478
      Value: 15 kW
    16. Create: Max. thermal power #3377479
      Value: 98.8 kW
    17. Create: Efficiency #3377480
      Value: 110 %
    18. Create: Heated area #3377481
      Value: 1000 m²
    19. Create: Maximum water pressure in the heating circuit #3377482
      Value: 6 bar
    20. Create: Minimum heating medium temperature #3377483
      Value: 30°C
    21. Create: Maximum coolant temperature #3377484
      Value: 90°C
    22. Create: Expansion tank volume #3377485
      Value: 12 l
    23. Create: Gas connection #3377486
      Value: 3/4"
    24. Create: Heating circuit connection #3377487
      Value: 1¼
    25. Create: Chimney diameter #3377488
      Value: 160 mm
    26. Create: Coaxial chimney diameter #3377489
      Value: 110/160 mm
    27. Create: Minimum temperature in the DHW circuit #3377490
      Value: 30°C
    28. Create: Fuel #3377491
      Value: Natural gas, liquefied gas
    29. Create: Permissible LPG pressure #3377492
      Value: 50 mbar
    30. Create: Natural gas consumption #3377493
      Value: 10.03 m³/h
    31. Create: LPG consumption #3377494
      Value: 7.44 kg/h
    32. Create: Depth #3377495
      Value: 548 mm
    33. Create: Weight #3377496
      Value: 92 kg
    34. Create: Image #6316760
      URL: https://avatars.mds.yandex.net/get-mpic/5350118/img_id393148115277813598.jpeg/orig
    35. Create: Image #6316761
      URL: https://avatars.mds.yandex.net/get-mpic/5334770/img_id437235959505078041.jpeg/orig
    36. Create: Image #6316762
      URL: https://avatars.mds.yandex.net/get-mpic/3939831/img_id288240797218494888.png/orig
    37. Create: Image #6316763
      URL: https://avatars.mds.yandex.net/get-mpic/4012371/img_id6627297594785124375.jpeg/orig
    38. Create: Image #6316764
      URL: https://avatars.mds.yandex.net/get-mpic/5236119/img_id6232267344623525797.jpeg/orig
    39. Create: Image #6316765
      URL: https://avatars.mds.yandex.net/get-mpic/1912364/img_id3016661748947034611.jpeg/orig
    40. Create: Image #6316766
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id557544742326180812.jpeg/orig
    41. Create: Image #6316767
      URL: https://avatars.mds.yandex.net/get-mpic/1923922/img_id7730803750025850927.jpeg/orig
    42. Create: Image #6316768
      URL: https://avatars.mds.yandex.net/get-mpic/7464534/img_id7858202146701091418.jpeg/orig
    43. Create: Image #6316769
      URL: https://avatars.mds.yandex.net/get-mpic/1537623/img_id4608584408276417681.jpeg/orig
    44. Create: Preview image #6316770
      URL: https://avatars.mds.yandex.net/get-mpic/5350118/img_id393148115277813598.jpeg/orig
  2. Donny Darko 30 April 2023 08:16:23
    Name: Gas wall mounted condensing boiler Wolf CGB-100; Catalog: Heating boilers