Change history for item: Gas wall double-circuit boiler Wolf CGG-3K-24

  1. Donny Darko 07 July 2023 18:18:10
    1. Create: Description #3377411
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3377412
      Value: Gas, convection
    3. Create: Burner #3377413
      Value: Gas
    4. Create: Number of circuits #3377414
      Value: Double-circuit
    5. Create: Thermal power #3377415
      Value: 10.90 - 24 kW
    6. Create: Thermal load #3377416
      Value: 11.50 - 25.80 kW
    7. Create: The combustion chamber #3377417
      Value: Closed
    8. Create: Efficiency #3377418
      Value: 92.2 %
    9. Create: Control #3377419
      Value: Electronic
    10. Create: Installation #3377420
      Value: Wall-mounted
    11. Create: Mains voltage #3377421
      Value: Single-phase
    12. Create: Peculiarities #3377422
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3377423
      Value: 8 l
    14. Create: Equipment #3377424
      Value: Display
    15. Create: Fuel #3377425
      Value: Natural gas
    16. Create: Natural gas consumption #3377426
      Value: 2.7 cu. m/hour
    17. Create: Nominal pressure of natural gas #3377427
      Value: 18 - 25 mbar
    18. Create: Heat carrier temperature #3377428
      Value: 45 - 85 °С
    19. Create: Temperature in the DHW circuit #3377429
      Value: 40 - 60 °С
    20. Create: Hot water capacity at t 30°C #3377430
      Value: 11.7 l/min
    21. Create: Max. water pressure in the DHW circuit #3377431
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3377432
      Value: 3 bar
    23. Create: Gas connection #3377433
      Value: 3/4"
    24. Create: Heating circuit connection #3377434
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3377435
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3377436
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3377437
      Value: 408x740x340mm
    28. Create: Weight #3377438
      Value: 34 kg
    29. Create: Image #6316749
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id8149189752203356415.jpeg/orig
    30. Create: Image #6316750
      URL: https://avatars.mds.yandex.net/get-mpic/4080484/img_id1864261038309169752.jpeg/orig
    31. Create: Preview image #6316751
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id8149189752203356415.jpeg/orig
  2. Donny Darko 30 April 2023 08:16:23
    Name: Gas wall double-circuit boiler Wolf CGG-3K-24; Catalog: Heating boilers