      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3377384
      Value: Gas, convection
    3. Create: Burner #3377385
      Value: Gas
    4. Create: Number of circuits #3377386
      Value: Double-circuit
    5. Create: Thermal power #3377387
      Value: 10.20 - 18 kW
    6. Create: Thermal load #3377388
      Value: 10.60 - 19.50 kW
    7. Create: The combustion chamber #3377389
      Value: Closed
    8. Create: Efficiency #3377390
      Value: 93.3 %
    9. Create: Control #3377391
      Value: Electronic
    10. Create: Installation #3377392
      Value: Wall-mounted
    11. Create: Mains voltage #3377393
      Value: Single-phase
    12. Create: Peculiarities #3377394
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3377395
      Value: 8 l
    14. Create: Equipment #3377396
      Value: Display
    15. Create: Fuel #3377397
      Value: Natural gas
    16. Create: Natural gas consumption #3377398
      Value: 2.1 cu. m/hour
    17. Create: Nominal pressure of natural gas #3377399
      Value: 18 - 25 mbar
    18. Create: Heat carrier temperature #3377400
      Value: 45 - 85 °С
    19. Create: Temperature in the DHW circuit #3377401
      Value: 40 - 60 °С
    20. Create: Hot water capacity at t 30°C #3377402
      Value: 8 l/min
    21. Create: Max. water pressure in the DHW circuit #3377403
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3377404
      Value: 3 bar
    23. Create: Gas connection #3377405
      Value: 3/4"
    24. Create: Heating circuit connection #3377406
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3377407
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3377408
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3377409
      Value: 408x740x340mm
    28. Create: Weight #3377410
      Value: 34 kg
    29. Create: Image #6316746
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id4443791546143367676.jpeg/orig
    30. Create: Image #6316747
      URL: https://avatars.mds.yandex.net/get-mpic/1581127/img_id3715952510876640911.jpeg/orig
    31. Create: Preview image #6316748
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id4443791546143367676.jpeg/orig
  2. Donny Darko 30 April 2023 08:16:22
    Name: Gas wall-mounted boiler WOLF CGG-3K-18; Catalog: Heating boilers