Change history for item: Gas boiler Wolf FGB-K-24 double-circuit

  1. Donny Darko 07 July 2023 18:17:30
    1. Create: Description #3377230
      Value: Type of heating boiler: gas, max. heating power: 19.40 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3377231
      Value: Gas, condensing
    3. Create: Burner #3377232
      Value: Gas
    4. Create: Number of circuits #3377233
      Value: Double-circuit
    5. Create: Thermal power #3377234
      Value: 4.80 - 19.40 kW
    6. Create: The combustion chamber #3377235
      Value: Closed
    7. Create: Efficiency #3377236
      Value: 110 %
    8. Create: Control #3377237
      Value: Electronic
    9. Create: Installation #3377238
      Value: Wall-mounted
    10. Create: Mains voltage #3377239
      Value: Single-phase
    11. Create: Peculiarities #3377240
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3377241
      Value: 8 l
    13. Create: Equipment #3377242
      Value: Display
    14. Create: Fuel #3377243
      Value: Natural gas, liquefied gas
    15. Create: Nominal pressure of natural gas #3377244
      Value: 18 - 25 mbar
    16. Create: Permissible LPG pressure #3377245
      Value: 35 mbar
    17. Create: Max. coolant temperature #3377246
      Value: 85 °С
    18. Create: Temperature in the DHW circuit #3377247
      Value: 30 - 65 °С
    19. Create: Hot water capacity at t 30°C #3377248
      Value: 10.6 l/min
    20. Create: Max. water pressure in the DHW circuit #3377249
      Value: 10 bar
    21. Create: Max. water pressure in the heating circuit #3377250
      Value: 3 bar
    22. Create: Gas connection #3377251
      Value: 1/2"
    23. Create: Heating circuit connection #3377252
      Value: 3/4"
    24. Create: Branch pipe for connecting the DHW circuit #3377253
      Value: 1/2"
    25. Create: Coaxial chimney diameter #3377254
      Value: 60/100 mm
    26. Create: Dimensions WxHxD #3377255
      Value: 408x650x310 mm
    27. Create: Weight #3377256
      Value: 27 kg
    28. Create: Image #6316681
      URL: https://avatars.mds.yandex.net/get-mpic/1970506/img_id6524151756944019990.jpeg/orig
    29. Create: Image #6316682
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id1033938581915535661.jpeg/orig
    30. Create: Image #6316683
      URL: https://avatars.mds.yandex.net/get-mpic/4397559/img_id4351295300520928511.jpeg/orig
    31. Create: Image #6316684
      URL: https://avatars.mds.yandex.net/get-mpic/5257660/img_id8871400867308621418.jpeg/orig
    32. Create: Image #6316685
      URL: https://avatars.mds.yandex.net/get-mpic/4448948/img_id6892094618093062160.jpeg/orig
    33. Create: Preview image #6316686
      URL: https://avatars.mds.yandex.net/get-mpic/1970506/img_id6524151756944019990.jpeg/orig
  2. Donny Darko 30 April 2023 08:16:20
    Name: Gas boiler Wolf FGB-K-24 double-circuit; Catalog: Heating boilers