Change history for item: Gas boiler Wolf FGB-K-28

  1. Donny Darko 07 July 2023 18:16:53
    1. Create: Description #3376956
      Value: Type of heating boiler: gas, max. heating power: 27.30 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3376957
      Value: Gas, convection
    3. Create: Burner #3376958
      Value: Gas
    4. Create: Number of circuits #3376959
      Value: Double-circuit
    5. Create: Thermal power #3376960
      Value: 4.80 - 27.30 kW
    6. Create: Thermal load #3376961
      Value: 4.90 - 25 kW
    7. Create: The combustion chamber #3376962
      Value: Closed
    8. Create: Efficiency #3376963
      Value: 109 %
    9. Create: Control #3376964
      Value: Electronic
    10. Create: Installation #3376965
      Value: Wall-mounted
    11. Create: Mains voltage #3376966
      Value: Single-phase
    12. Create: Peculiarities #3376967
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, external control connector, thermometer, water filter
    13. Create: Expansion tank volume #3376968
      Value: 8 l
    14. Create: Equipment #3376969
      Value: Display
    15. Create: Fuel #3376970
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3376971
      Value: 3.25 cu. m/hour
    17. Create: LPG consumption #3376972
      Value: 2.18 kg/hour
    18. Create: Nominal pressure of natural gas #3376973
      Value: 18 - 25 mbar
    19. Create: Permissible LPG pressure #3376974
      Value: 35 mbar
    20. Create: Max. coolant temperature #3376975
      Value: 85 °С
    21. Create: Temperature in the DHW circuit #3376976
      Value: 30 - 65 °С
    22. Create: Hot water capacity at t 30°C #3376977
      Value: 13.4 l/min
    23. Create: Max. water pressure in the DHW circuit #3376978
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3376979
      Value: 3 bar
    25. Create: Gas connection #3376980
      Value: 1/2"
    26. Create: Heating circuit connection #3376981
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3376982
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3376983
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3376984
      Value: 408x650x310 mm
    30. Create: Weight #3376985
      Value: 30 kg
    31. Create: Image #6316603
      URL: https://avatars.mds.yandex.net/get-mpic/1865271/img_id6163863412299075837/orig
    32. Create: Image #6316604
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id1033938581915535661.jpeg/orig
    33. Create: Image #6316605
      URL: https://avatars.mds.yandex.net/get-mpic/5257660/img_id8871400867308621418.jpeg/orig
    34. Create: Preview image #6316606
      URL: https://avatars.mds.yandex.net/get-mpic/1865271/img_id6163863412299075837/orig
  2. Donny Darko 30 April 2023 08:16:17
    Name: Gas boiler Wolf FGB-K-28; Catalog: Heating boilers