    1. Create: Description #3376699
      Value: Type of heating boiler: gas, max. heating power: 15.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3376700
      Value: Gas, condensing
    3. Create: Burner #3376701
      Value: Gas
    4. Create: Number of circuits #3376702
      Value: Double-circuit
    5. Create: Thermal power #3376703
      Value: 1.80 - 15.20 kW
    6. Create: Thermal load #3376704
      Value: 1.90 - 14 kW
    7. Create: The combustion chamber #3376705
      Value: Closed
    8. Create: Efficiency #3376706
      Value: 110 %
    9. Create: Control #3376707
      Value: Electronic
    10. Create: Installation #3376708
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3376709
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3376710
      Value: Stainless steel
    13. Create: Mains voltage #3376711
      Value: Single-phase
    14. Create: Peculiarities #3376712
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, external control connector, thermometer
    15. Create: The volume of the built-in boiler #3376713
      Value: 120 l
    16. Create: Expansion tank volume #3376714
      Value: 10 l
    17. Create: Equipment #3376715
      Value: Built-in boiler, display
    18. Create: Fuel #3376716
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3376717
      Value: 1.59 cu. m/hour
    20. Create: LPG consumption #3376718
      Value: 1.07 kg/hour
    21. Create: Nominal pressure of natural gas #3376719
      Value: 20 mbar
    22. Create: Permissible LPG pressure #3376720
      Value: 50 mbar
    23. Create: Max. coolant temperature #3376721
      Value: 90 °С
    24. Create: Temperature in the DHW circuit #3376722
      Value: 15 - 65 °С
    25. Create: Hot water capacity at t 30°C #3376723
      Value: 18.7 l/min
    26. Create: Max. water pressure in the DHW circuit #3376724
      Value: 10 bar
    27. Create: Max. water pressure in the heating circuit #3376725
      Value: 3 bar
    28. Create: Gas connection #3376726
      Value: 1/2"
    29. Create: Heating circuit connection #3376727
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3376728
      Value: 3/4"
    31. Create: Coaxial chimney diameter #3376729
      Value: 60/100 mm and 80/125 mm
    32. Create: Dimensions WxHxD #3376730
      Value: 600x1462x635mm
    33. Create: Weight #3376731
      Value: 8.5 kg
    34. Create: Image #6316566
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id1613256660959550315.jpeg/orig
    35. Create: Image #6316567
      URL: https://avatars.mds.yandex.net/get-mpic/4262452/img_id1358746227705108293.jpeg/orig
    36. Create: Preview image #6316568
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id1613256660959550315.jpeg/orig
  2. Donny Darko 30 April 2023 08:16:15
    Name: Gas boiler Wolf CGS-2-14/120L; Catalog: Heating boilers