Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 18:15:30
Create:
Description #3376350
Value: Type of heating boiler: gas, max. heating power: 20.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3376351
Value: Gas, condensing
Create:
Burner #3376352
Value: Gas
Create:
Number of circuits #3376353
Value: Double-circuit
Create:
Thermal power #3376354
Value: 3.80 - 20.40 kW
Create:
Thermal load #3376355
Value: 3.90 - 19.60 kW
Create:
The combustion chamber #3376356
Value: Closed
Create:
Efficiency #3376357
Value: 110 %
Create:
Control #3376358
Value: Electronic
Create:
Installation #3376359
Value: Wall-mounted
Create:
Primary heat exchanger material #3376360
Value: Stainless steel
Create:
Secondary heat exchanger material #3376361
Value: Stainless steel
Create:
Mains voltage #3376362
Value: Single-phase
Create:
Peculiarities #3376363
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, external control connector, thermometer
Create:
Expansion tank volume #3376364
Value: 10 l
Create:
Equipment #3376365
Value: Display
Create:
Fuel #3376366
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3376367
Value: 22.8 cu. m/hour
Create:
LPG consumption #3376368
Value: 1.53 kg/h
Create:
Nominal pressure of natural gas #3376369
Value: 20 mbar
Create:
Permissible LPG pressure #3376370
Value: 50 mbar
Create:
Max. coolant temperature #3376371
Value: 90 °С
Create:
Temperature in the DHW circuit #3376372
Value: 45 - 65 °С
Create:
Hot water capacity at t 30°C #3376373
Value: 10.3 l/min
Create:
Max. water pressure in the DHW circuit #3376374
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3376375
Value: 3 bar
Create:
Gas connection #3376376
Value: 1/2"
Create:
Heating circuit connection #3376377
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3376378
Value: 3/4"
Create:
Coaxial chimney diameter #3376379
Value: 60/100 mm and 80/125 mm
Create:
Dimensions WxHxD #3376380
Value: 440x790x378 mm
Create:
Weight #3376381
Value: 35 kg
Create:
Image #6316518
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id330093819393381652/orig
Create:
Image #6316519
URL: https://avatars.mds.yandex.net/get-mpic/4809583/img_id530861395269459223.png/orig
Create:
Image #6316520
URL: https://avatars.mds.yandex.net/get-mpic/1733932/img_id1338713438245930323.jpeg/orig
Create:
Image #6316521
URL: https://avatars.mds.yandex.net/get-mpic/1715213/img_id4117070810020386456.jpeg/orig
Create:
Image #6316522
URL: https://avatars.mds.yandex.net/get-mpic/4076910/img_id3568206215567132622.jpeg/orig
Create:
Image #6316523
URL: https://avatars.mds.yandex.net/get-mpic/5234083/img_id6894806884594243324.jpeg/orig
Create:
Preview image #6316524
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id330093819393381652/orig
Donny Darko 30 April 2023 08:16:12
Name: Gas boiler Wolf CGB-2K-20; Catalog: Heating boilers