Change history for item: Gas boiler Wolf CGB-2K-20

  1. Donny Darko 07 July 2023 18:15:30
    1. Create: Description #3376350
      Value: Type of heating boiler: gas, max. heating power: 20.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3376351
      Value: Gas, condensing
    3. Create: Burner #3376352
      Value: Gas
    4. Create: Number of circuits #3376353
      Value: Double-circuit
    5. Create: Thermal power #3376354
      Value: 3.80 - 20.40 kW
    6. Create: Thermal load #3376355
      Value: 3.90 - 19.60 kW
    7. Create: The combustion chamber #3376356
      Value: Closed
    8. Create: Efficiency #3376357
      Value: 110 %
    9. Create: Control #3376358
      Value: Electronic
    10. Create: Installation #3376359
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3376360
      Value: Stainless steel
    12. Create: Secondary heat exchanger material #3376361
      Value: Stainless steel
    13. Create: Mains voltage #3376362
      Value: Single-phase
    14. Create: Peculiarities #3376363
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, external control connector, thermometer
    15. Create: Expansion tank volume #3376364
      Value: 10 l
    16. Create: Equipment #3376365
      Value: Display
    17. Create: Fuel #3376366
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3376367
      Value: 22.8 cu. m/hour
    19. Create: LPG consumption #3376368
      Value: 1.53 kg/h
    20. Create: Nominal pressure of natural gas #3376369
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3376370
      Value: 50 mbar
    22. Create: Max. coolant temperature #3376371
      Value: 90 °С
    23. Create: Temperature in the DHW circuit #3376372
      Value: 45 - 65 °С
    24. Create: Hot water capacity at t 30°C #3376373
      Value: 10.3 l/min
    25. Create: Max. water pressure in the DHW circuit #3376374
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3376375
      Value: 3 bar
    27. Create: Gas connection #3376376
      Value: 1/2"
    28. Create: Heating circuit connection #3376377
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3376378
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3376379
      Value: 60/100 mm and 80/125 mm
    31. Create: Dimensions WxHxD #3376380
      Value: 440x790x378 mm
    32. Create: Weight #3376381
      Value: 35 kg
    33. Create: Image #6316518
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id330093819393381652/orig
    34. Create: Image #6316519
      URL: https://avatars.mds.yandex.net/get-mpic/4809583/img_id530861395269459223.png/orig
    35. Create: Image #6316520
      URL: https://avatars.mds.yandex.net/get-mpic/1733932/img_id1338713438245930323.jpeg/orig
    36. Create: Image #6316521
      URL: https://avatars.mds.yandex.net/get-mpic/1715213/img_id4117070810020386456.jpeg/orig
    37. Create: Image #6316522
      URL: https://avatars.mds.yandex.net/get-mpic/4076910/img_id3568206215567132622.jpeg/orig
    38. Create: Image #6316523
      URL: https://avatars.mds.yandex.net/get-mpic/5234083/img_id6894806884594243324.jpeg/orig
    39. Create: Preview image #6316524
      URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id330093819393381652/orig
  2. Donny Darko 30 April 2023 08:16:12
    Name: Gas boiler Wolf CGB-2K-20; Catalog: Heating boilers