Change history for item: Gas boiler Wolf CGG-2K-18 18 kW double-circuit

  1. Donny Darko 07 July 2023 18:11:52
    1. Create: Description #3375293
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3375294
      Value: Gas, convection
    3. Create: Burner #3375295
      Value: Gas
    4. Create: Number of circuits #3375296
      Value: Double-circuit
    5. Create: Thermal power #3375297
      Value: 8 - 18 kW
    6. Create: Thermal load #3375298
      Value: 8.50 - 19.70 kW
    7. Create: The combustion chamber #3375299
      Value: Closed
    8. Create: Efficiency #3375300
      Value: 94 %
    9. Create: Control #3375301
      Value: Electronic
    10. Create: Installation #3375302
      Value: Wall-mounted
    11. Create: Mains voltage #3375303
      Value: Single-phase
    12. Create: Peculiarities #3375304
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Expansion tank volume #3375305
      Value: 10 l
    14. Create: Fuel #3375306
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3375307
      Value: 2.1 cu. m/hour
    16. Create: LPG consumption #3375308
      Value: 1.5 kg/hour
    17. Create: Nominal pressure of natural gas #3375309
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3375310
      Value: 50 mbar
    19. Create: Heat carrier temperature #3375311
      Value: 40 - 90 °С
    20. Create: Temperature in the DHW circuit #3375312
      Value: 40 - 60 °С
    21. Create: Hot water capacity at t 30°C #3375313
      Value: 8.7 l/min
    22. Create: Max. water pressure in the DHW circuit #3375314
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3375315
      Value: 3 bar
    24. Create: Gas connection #3375316
      Value: 3/4"
    25. Create: Heating circuit connection #3375317
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3375318
      Value: 3/4"
    27. Create: Coaxial chimney diameter #3375319
      Value: 60/100 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3375320
      Value: Yes
    29. Create: Dimensions WxHxD #3375321
      Value: 440x855x393 mm
    30. Create: Weight #3375322
      Value: 42 kg
    31. Create: Image #6316412
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1387750247634528483/orig
    32. Create: Preview image #6316413
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1387750247634528483/orig
  2. Donny Darko 30 April 2023 08:15:58
    Name: Gas boiler Wolf CGG-2K-18 18 kW double-circuit; Catalog: Heating boilers