Change history for item: Gas boiler Wolf CGU-2 K-18

  1. Donny Darko 07 July 2023 18:11:38
    1. Create: Description #3375181
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3375182
      Value: Gas, convection
    3. Create: Burner #3375183
      Value: Gas
    4. Create: Number of circuits #3375184
      Value: Double-circuit
    5. Create: Thermal power #3375185
      Value: 8 - 18 kW
    6. Create: Thermal load #3375186
      Value: 8.80 - 20.20 kW
    7. Create: The combustion chamber #3375187
      Value: Open
    8. Create: Efficiency #3375188
      Value: 93 %
    9. Create: Control #3375189
      Value: Electronic
    10. Create: Installation #3375190
      Value: Wall-mounted
    11. Create: Mains voltage #3375191
      Value: Single-phase
    12. Create: Peculiarities #3375192
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Expansion tank volume #3375193
      Value: 10 l
    14. Create: Equipment #3375194
      Value: Display
    15. Create: Fuel #3375195
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3375196
      Value: 2.1 cu. m/hour
    17. Create: LPG consumption #3375197
      Value: 1.5 kg/hour
    18. Create: Nominal pressure of natural gas #3375198
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3375199
      Value: 50 mbar
    20. Create: Heat carrier temperature #3375200
      Value: 40 - 90 °С
    21. Create: Temperature in the DHW circuit #3375201
      Value: 40 - 60 °С
    22. Create: Hot water capacity at t 30°C #3375202
      Value: 8.7 l/min
    23. Create: Max. water pressure in the DHW circuit #3375203
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3375204
      Value: 3 bar
    25. Create: Gas connection #3375205
      Value: 3/4"
    26. Create: Heating circuit connection #3375206
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3375207
      Value: 3/4"
    28. Create: Chimney diameter #3375208
      Value: 110 mm
    29. Create: Dimensions WxHxD #3375209
      Value: 440x855x393 mm
    30. Create: Weight #3375210
      Value: 39 kg
    31. Create: Image #6316402
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1387750247634528483/orig
    32. Create: Preview image #6316403
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id1387750247634528483/orig
  2. Donny Darko 30 April 2023 08:15:57
    Name: Gas boiler Wolf CGU-2 K-18; Catalog: Heating boilers