Change history for item: Gas boiler Wolf CGB-K-40-35

  1. Donny Darko 07 July 2023 18:11:13
    1. Create: Description #3375018
      Value: Type of heating boiler: gas, max. thermal power: 39 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3375019
      Value: Gas, condensing
    3. Create: Burner #3375020
      Value: Gas
    4. Create: Number of circuits #3375021
      Value: Double-circuit
    5. Create: Thermal power #3375022
      Value: 9 - 39 kW
    6. Create: Thermal load #3375023
      Value: 8.50 - 33 kW
    7. Create: The combustion chamber #3375024
      Value: Closed
    8. Create: Efficiency #3375025
      Value: 106 %
    9. Create: Control #3375026
      Value: Electronic
    10. Create: Installation #3375027
      Value: Wall-mounted
    11. Create: Mains voltage #3375028
      Value: Single-phase
    12. Create: Peculiarities #3375029
      Value: Air vent, built-in circulation pump, pressure gauge, safety valve, thermometer
    13. Create: Fuel #3375030
      Value: Natural gas, liquefied gas
    14. Create: Natural gas consumption #3375031
      Value: 4.34 cu. m/hour
    15. Create: LPG consumption #3375032
      Value: 3.4 kg/hour
    16. Create: Nominal pressure of natural gas #3375033
      Value: 20 mbar
    17. Create: Permissible LPG pressure #3375034
      Value: 50 mbar
    18. Create: Max. coolant temperature #3375035
      Value: 90 °С
    19. Create: Temperature in the DHW circuit #3375036
      Value: 40 - 60 °С
    20. Create: Hot water capacity at t 30°C #3375037
      Value: 12 l/min
    21. Create: Max. water pressure in the DHW circuit #3375038
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3375039
      Value: 3 bar
    23. Create: Gas connection #3375040
      Value: 3/4"
    24. Create: Heating circuit connection #3375041
      Value: 1¼
    25. Create: Branch pipe for connecting the DHW circuit #3375042
      Value: 3/4"
    26. Create: Coaxial chimney diameter #3375043
      Value: 80/125 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3375044
      Value: Yes
    28. Create: Dimensions WxHxD #3375045
      Value: 400x855x393 mm
    29. Create: Weight #3375046
      Value: 45 kg
    30. Create: Image #6316387
      URL: https://avatars.mds.yandex.net/get-mpic/1750349/img_id2050419449079352096/orig
    31. Create: Image #6316388
      URL: https://avatars.mds.yandex.net/get-mpic/4303439/img_id3611971944535303516.jpeg/orig
    32. Create: Preview image #6316389
      URL: https://avatars.mds.yandex.net/get-mpic/1750349/img_id2050419449079352096/orig
  2. Donny Darko 30 April 2023 08:15:56
    Name: Gas boiler Wolf CGB-K-40-35; Catalog: Heating boilers