Change history for item: Gas boiler Wolf CGS-20/160 22.9 kW double-circuit

  1. Donny Darko 07 July 2023 18:11:03
    1. Create: Description #3374954
      Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3374955
      Value: Gas, condensing
    3. Create: Burner #3374956
      Value: Gas
    4. Create: Number of circuits #3374957
      Value: Double-circuit
    5. Create: Thermal power #3374958
      Value: 5.60 - 22.90 kW
    6. Create: Thermal load #3374959
      Value: 5.70 - 23.50 kW
    7. Create: The combustion chamber #3374960
      Value: Closed
    8. Create: Efficiency #3374961
      Value: 105 %
    9. Create: Control #3374962
      Value: Electronic
    10. Create: Installation #3374963
      Value: Floor
    11. Create: Primary heat exchanger material #3374964
      Value: Stainless steel
    12. Create: Mains voltage #3374965
      Value: Single-phase
    13. Create: Peculiarities #3374966
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
    14. Create: The volume of the built-in boiler #3374967
      Value: 160 l
    15. Create: Expansion tank volume #3374968
      Value: 12 l
    16. Create: Equipment #3374969
      Value: Built-in boiler
    17. Create: Fuel #3374970
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3374971
      Value: 2.47 cu. m/hour
    19. Create: LPG consumption #3374972
      Value: 1.84 kg/hour
    20. Create: Nominal pressure of natural gas #3374973
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3374974
      Value: 50 mbar
    22. Create: Max. coolant temperature #3374975
      Value: 90 °С
    23. Create: Temperature in the DHW circuit #3374976
      Value: 15 - 65 °С
    24. Create: Hot water capacity at t 30°C #3374977
      Value: 23.2 l/min
    25. Create: Max. water pressure in the DHW circuit #3374978
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3374979
      Value: 3 bar
    27. Create: Gas connection #3374980
      Value: 1/2"
    28. Create: Heating circuit connection #3374981
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3374982
      Value: 3/4"
    30. Create: Coaxial chimney diameter #3374983
      Value: 60/100 mm and 80/125 mm
    31. Create: Dimensions WxHxD #3374984
      Value: 566x1469x637 mm
    32. Create: Weight #3374985
      Value: 99 kg
    33. Create: Image #6316383
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id6806754557117561807/orig
    34. Create: Preview image #6316384
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id6806754557117561807/orig
  2. Donny Darko 30 April 2023 08:15:55
    Name: Gas boiler Wolf CGS-20/160 22.9 kW double-circuit; Catalog: Heating boilers