Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 18:07:05
Create:
Description #3374118
Value: Type of heating boiler: gas, max. heating power: 17.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3374119
Value: Gas, convection
Create:
Burner #3374120
Value: Gas
Create:
Number of circuits #3374121
Value: Double-circuit
Create:
Thermal power #3374122
Value: 7.50 - 17.80 kW
Create:
Thermal load #3374123
Value: 7.50 - 17.80 kW
Create:
The combustion chamber #3374124
Value: Closed
Create:
Heated area #3374125
Value: 180 sq.m
Create:
Efficiency #3374126
Value: 90 %
Create:
Control #3374127
Value: Electronic
Create:
Installation #3374128
Value: Wall-mounted
Create:
Primary heat exchanger material #3374129
Value: Copper
Create:
Secondary heat exchanger material #3374130
Value: Stainless steel
Create:
Mains voltage #3374131
Value: Single-phase
Create:
Peculiarities #3374132
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
Create:
Expansion tank volume #3374133
Value: 6 l
Create:
Equipment #3374134
Value: Built-in exhaust fan, display
Create:
Fuel #3374135
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3374136
Value: 2.12 cu. m/hour
Create:
LPG consumption #3374137
Value: 0.8 kg/hour
Create:
Nominal pressure of natural gas #3374138
Value: 20 mbar
Create:
Permissible LPG pressure #3374139
Value: 28 mbar
Create:
Heat carrier temperature #3374140
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3374141
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3374142
Value: 13 l/min
Create:
Hot water capacity at t 30°C #3374143
Value: 10.8 l/min
Create:
Max. water pressure in the DHW circuit #3374144
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3374145
Value: 3 bar
Create:
Gas connection #3374146
Value: 3/4"
Create:
Heating circuit connection #3374147
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3374148
Value: 1/2"
Create:
Chimney diameter #3374149
Value: 80 mm
Create:
Coaxial chimney diameter #3374150
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3374151
Value: Yes
Create:
Dimensions WxHxD #3374152
Value: 420x700x240mm
Create:
Weight #3374153
Value: 30 kg
Create:
Video #606
URL: https://frontend.vh.yandex.ru/player/48093f6e106ecea98b2c0b941001114e
Create:
Image #6316153
URL: https://avatars.mds.yandex.net/get-mpic/5236357/img_id8772129714680797094.jpeg/orig
Create:
Image #6316154
URL: https://avatars.mds.yandex.net/get-mpic/5255532/img_id6857629635149943077.png/orig
Create:
Image #6316155
URL: https://avatars.mds.yandex.net/get-mpic/4490717/img_id6365766241364814328.png/orig
Create:
Image #6316156
URL: https://avatars.mds.yandex.net/get-mpic/3986581/img_id2704368593983867523.jpeg/orig
Create:
Image #6316157
URL: https://avatars.mds.yandex.net/get-mpic/1970506/img_id4973359756864657246.jpeg/orig
Create:
Image #6316158
URL: https://avatars.mds.yandex.net/get-mpic/1886039/img_id5058430648909029021.jpeg/orig
Create:
Image #6316159
URL: https://avatars.mds.yandex.net/get-mpic/8109518/img_id647481390687826810.jpeg/orig
Create:
Preview image #6316160
URL: https://avatars.mds.yandex.net/get-mpic/5236357/img_id8772129714680797094.jpeg/orig
Donny Darko 30 April 2023 08:15:39
Name: Wall mounted gas Kentatsu Nobby Balance Plus 18-2CS; Catalog: Heating boilers