Change history for item: Gas Kentatsu Nobby Balance 46-2CS 41.8 kW double-circuit

  1. Donny Darko 07 July 2023 18:06:20
    1. Create: Description #3373839
      Value: Type of heating boiler: gas, max. heating power: 41.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3373840
      Value: Gas, convection
    3. Create: Burner #3373841
      Value: Gas
    4. Create: Number of circuits #3373842
      Value: Double-circuit
    5. Create: Thermal power #3373843
      Value: 12.60 - 41.80 kW
    6. Create: Thermal load #3373844
      Value: 13.80 - 46 kW
    7. Create: The combustion chamber #3373845
      Value: Closed
    8. Create: Efficiency #3373846
      Value: 91.5 %
    9. Create: Control #3373847
      Value: Electronic
    10. Create: Installation #3373848
      Value: Wall-mounted
    11. Create: Mains voltage #3373849
      Value: Single-phase
    12. Create: Peculiarities #3373850
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
    13. Create: Expansion tank volume #3373851
      Value: 8 l
    14. Create: Equipment #3373852
      Value: Built-in exhaust fan, display
    15. Create: Fuel #3373853
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3373854
      Value: 4.18 cu. m/hour
    17. Create: LPG consumption #3373855
      Value: 4.14 kg/hour
    18. Create: Nominal pressure of natural gas #3373856
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3373857
      Value: 28 mbar
    20. Create: Heat carrier temperature #3373858
      Value: 35 - 85 °С
    21. Create: Temperature in the DHW circuit #3373859
      Value: 35 - 65 °С
    22. Create: Hot water capacity at t 25°C #3373860
      Value: 24 l/min
    23. Create: Hot water capacity at t 30°C #3373861
      Value: 19.9 l/min
    24. Create: Max. water pressure in the DHW circuit #3373862
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3373863
      Value: 3 bar
    26. Create: Gas connection #3373864
      Value: 3/4"
    27. Create: Heating circuit connection #3373865
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3373866
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3373867
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3373868
      Value: Yes
    31. Create: Dimensions WxHxD #3373869
      Value: 590x740x320mm
    32. Create: Weight #3373870
      Value: 48 kg
    33. Create: Image #6316063
      URL: https://avatars.mds.yandex.net/get-mpic/4372348/img_id6090176829423348501.jpeg/orig
    34. Create: Preview image #6316064
      URL: https://avatars.mds.yandex.net/get-mpic/4372348/img_id6090176829423348501.jpeg/orig
  2. Donny Darko 30 April 2023 08:15:35
    Name: Gas Kentatsu Nobby Balance 46-2CS 41.8 kW double-circuit; Catalog: Heating boilers