Change history for item: Gas Kentatsu Nobby Balance 24-2CS 24 kW double-circuit

  1. Donny Darko 07 July 2023 18:05:00
    1. Create: Description #3373284
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3373285
      Value: Gas, convection
    3. Create: Burner #3373286
      Value: Gas
    4. Create: Number of circuits #3373287
      Value: Double-circuit
    5. Create: Thermal power #3373288
      Value: 7.20 - 24 kW
    6. Create: The combustion chamber #3373289
      Value: Closed
    7. Create: Efficiency #3373290
      Value: 92 %
    8. Create: Control #3373291
      Value: Electronic
    9. Create: Installation #3373292
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3373293
      Value: Copper
    11. Create: Mains voltage #3373294
      Value: Single-phase
    12. Create: Peculiarities #3373295
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3373296
      Value: 6 l
    14. Create: Equipment #3373297
      Value: Built-in exhaust fan, display
    15. Create: Natural gas consumption #3373298
      Value: 2.37 cu. m/hour
    16. Create: LPG consumption #3373299
      Value: 2.09 kg/h
    17. Create: Nominal pressure of natural gas #3373300
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3373301
      Value: 28 mbar
    19. Create: Heat carrier temperature #3373302
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3373303
      Value: 35 - 65 °С
    21. Create: Hot water capacity at t 25°C #3373304
      Value: 12 l/min
    22. Create: Hot water capacity at t 30°C #3373305
      Value: 10 l/min
    23. Create: Max. water pressure in the DHW circuit #3373306
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3373307
      Value: 3 bar
    25. Create: Gas connection #3373308
      Value: 3/4"
    26. Create: Heating circuit connection #3373309
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3373310
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3373311
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3373312
      Value: Yes
    30. Create: Dimensions WxHxD #3373313
      Value: 410x740x295 mm
    31. Create: Weight #3373314
      Value: 35 kg
    32. Create: Image #6315971
      URL: https://avatars.mds.yandex.net/get-mpic/3698270/img_id8068633350538244398.jpeg/orig
    33. Create: Image #6315972
      URL: https://avatars.mds.yandex.net/get-mpic/4012371/img_id3148329954944840586.jpeg/orig
    34. Create: Image #6315973
      URL: https://avatars.mds.yandex.net/get-mpic/4585707/img_id8401276290533283473.png/orig
    35. Create: Preview image #6315974
      URL: https://avatars.mds.yandex.net/get-mpic/3698270/img_id8068633350538244398.jpeg/orig
  2. Donny Darko 30 April 2023 08:15:29
    Name: Gas Kentatsu Nobby Balance 24-2CS 24 kW double-circuit; Catalog: Heating boilers