Change history for item: Gas Kentatsu Nobby Balance 28-2CS 28 kW double-circuit

  1. Donny Darko 07 July 2023 18:04:51
    1. Create: Description #3373217
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3373218
      Value: Gas, convection
    3. Create: Burner #3373219
      Value: Gas
    4. Create: Number of circuits #3373220
      Value: Double-circuit
    5. Create: Thermal power #3373221
      Value: 8.40 - 28 kW
    6. Create: The combustion chamber #3373222
      Value: Closed
    7. Create: Efficiency #3373223
      Value: 92.5 %
    8. Create: Control #3373224
      Value: Electronic
    9. Create: Installation #3373225
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3373226
      Value: Copper
    11. Create: Mains voltage #3373227
      Value: Single-phase
    12. Create: Peculiarities #3373228
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3373229
      Value: 6 l
    14. Create: Equipment #3373230
      Value: Built-in exhaust fan, display
    15. Create: Natural gas consumption #3373231
      Value: 2.77 cu. m/hour
    16. Create: LPG consumption #3373232
      Value: 2.51 kg/h
    17. Create: Nominal pressure of natural gas #3373233
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3373234
      Value: 28 mbar
    19. Create: Heat carrier temperature #3373235
      Value: 30 - 85 °С
    20. Create: Temperature in the DHW circuit #3373236
      Value: 35 - 65 °С
    21. Create: Hot water capacity at t 25°C #3373237
      Value: 14 l/min
    22. Create: Hot water capacity at t 30°C #3373238
      Value: 11.7 l/min
    23. Create: Max. water pressure in the DHW circuit #3373239
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3373240
      Value: 3 bar
    25. Create: Gas connection #3373241
      Value: 3/4"
    26. Create: Heating circuit connection #3373242
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3373243
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3373244
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3373245
      Value: Yes
    30. Create: Dimensions WxHxD #3373246
      Value: 470x740x300 mm
    31. Create: Weight #3373247
      Value: 39 kg
    32. Create: Image #6315961
      URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id5424958224186096268.jpeg/orig
    33. Create: Preview image #6315962
      URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id5424958224186096268.jpeg/orig
  2. Donny Darko 30 April 2023 08:15:29
    Name: Gas Kentatsu Nobby Balance 28-2CS 28 kW double-circuit; Catalog: Heating boilers